What is CRGO?

Cold-Rolled Grain Oriented silicon steel. Used in transformer core laminations. whatisCRNO? in transformers


During core bulding process why crgo lemination are used?

Transformer cores are chosen to limit eddy currents, which cause heating and losses in the core. Very thin laminations minimize this overhead cost of running a transformer by reducing losses associated with eddy currents.


What is the difference between CRGO steel and normal steel?

CRGO stands for :COLD ROLLED GRAIN ORIENTATION which is used in transformer core assembly.Transformer problem occours 40% because of using Non prime CRGO as lndustries are using frequently so life of transformer reduces.Both have different chemical composition like amount of silicon differs.Rest of difference you can see through net like density diffrence and their chemical and mechanical properties.Thanks


Why laminations are used for iron parts of a dc machine?

Laminations minimize eddy currents, or current flow across the iron parts. This is one method to minimze stray losses.


Lamination of the iron core is used to reduce eddy current due to?

The laminations on the core of a transformer are actually insulated from each other. This means that there is no circuit for current to flow, but since the laminations are stacked in an alternating orientation, there is magnetic coupling. If the core were one piece, or the laminations where allowed to touch each other electrically, there would be current flow, i.e. eddy current flow, because the core would represent a one turn secondary that is shorted. This means low voltage, but high current capacity. This means power loss, and degradation of Q and efficiency in the transformer.

Related questions

What is CRGO?

Cold-Rolled Grain Oriented silicon steel. Used in transformer core laminations. whatisCRNO? in transformers


During core bulding process why crgo lemination are used?

Transformer cores are chosen to limit eddy currents, which cause heating and losses in the core. Very thin laminations minimize this overhead cost of running a transformer by reducing losses associated with eddy currents.


What is the Technical meaning of CRGO Lamination?

To minimize hysteresis loss


The reasons for using laminations in the core of some electromegnets is to?

To decrease eddy currents in the core which result in heating / extra losses. The thinner the laminations, the more effective this is.


What is the difference between CRGO steel and normal steel?

CRGO stands for :COLD ROLLED GRAIN ORIENTATION which is used in transformer core assembly.Transformer problem occours 40% because of using Non prime CRGO as lndustries are using frequently so life of transformer reduces.Both have different chemical composition like amount of silicon differs.Rest of difference you can see through net like density diffrence and their chemical and mechanical properties.Thanks


Were laminations used in World War 2?

Yes


Why laminations are used for iron parts of a dc machine?

Laminations minimize eddy currents, or current flow across the iron parts. This is one method to minimze stray losses.


How do you make handmade carton strong enough for a box?

If your using card stock, or cardboard, the key is laminations & glue. (don't use flexible glues, use glues like plastic resin glues that dry hard) also depending on size: larger, more laminations. Smaller less laminations. If you want it as sturdy as a wood box, again more laminations, and you must glue both sides of all interior cardboards. Good-Luck


How are slate and shale alike?

Dark Colour, Clay mineral composition (Kaolanite), Laminations of minerals


Lamination of the iron core is used to reduce eddy current due to?

The laminations on the core of a transformer are actually insulated from each other. This means that there is no circuit for current to flow, but since the laminations are stacked in an alternating orientation, there is magnetic coupling. If the core were one piece, or the laminations where allowed to touch each other electrically, there would be current flow, i.e. eddy current flow, because the core would represent a one turn secondary that is shorted. This means low voltage, but high current capacity. This means power loss, and degradation of Q and efficiency in the transformer.


What prevents transformer laminationsfrom shorting to the adjacent laminations?

You need to prevent transformer laminations from shorting to each other because, otherwise, there would be eddy currents that affect the Q of the transformer, effectively impacting its efficiency. They would also cause the transformer to run hot. If the laminations were not insulated from each other, they would constitute a one-turn shorted winding, with high internal current. Usually, the laminations, in the shape of an E, are inserted into the windings alternately from each end, enhancing magnetic coupling while not causing the one-turn short. This is the same issue involving routing a conductor through a hole in a panel - the hole must be relieved, or slotted, to prevent eddy current, or (better) both conductors must be routed through the same hole, balancing the current, resulting in no eddy current.


Why lamination of different length of leaf springs use in automobiles?

because the stress developed at centre is maximum that is why there is no need for full length progressive laminations.