answersLogoWhite

0

What is T8 stands for T8 lamps?

Updated: 11/22/2022
User Avatar

Wiki User

14y ago

Best Answer

Fluorescent tubes are measured in 1/8ths of an inch. A T8 would be 8/8ths or one inch. Likewise a T12 would be 12/8ths or one and a half inches.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is T8 stands for T8 lamps?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you use a 4ft 4 lamps T8 ballast to run 4 18in T8 lamps?

You need to match the specification for the T8 lamps in question with the ballast. There are some times form factor issues and other times the specific requirements for the lamp in question.


What is the three types of hot-cathode fluorescent lamps?

The three types of hot-cathode fluorescent lamps are T12, T8, and T5. T12 lamps are the oldest and largest, T8 lamps are more energy-efficient and commonly used in commercial applications, and T5 lamps are the smallest and most efficient, often used in task lighting or compact installations.


Can you replace t8 bulb in fixture now using t12 bulb?

Yes a T12 lamp socket will take a T8 tube. The T8 tube will not operate. The T8 ballast is an electronic ballast where as the T12 ballast is a magnetic type. If you are changing over fluorescent fixtures to the smaller T8 lamps then the ballast has to be changed and the end sockets have to be rewired. The schematic on how to do the rewire is on the electronic ballast's label.


Difference between T12 and T8 fluorescent bulbs?

A T8 lamp can be retro fitted into a T12 fixture by replacing the T12 ballast with a T8 ballast. The end sockets also have to be rewired in the retrofit as the wiring from the electronic ballast to the sockets is completely different.


Is a T8 ballast and T8 bulb more efficient then a T12 ballast and a T8 bulb?

In a T* ballast and T8 bulb more energy efficient then a T12 ballast and a T8 bulb? A:Depends on the CURRENT through the tube. When the Tube is run at 100% of rating, The T12 Takes more CURRENT to give a certain Brightness. Because the surface of the T8 is closer to the ion stream through the tube, it takes less CURRENT to light up the T8 to the same brightness. However, IF you use a T12 in a T8 ballast, you will get LESS CURRENT through the tube, and LESS POWER consumed ALONG with LESS Light.

Related questions

Can you use a 4ft 4 lamps T8 ballast to run 4 18in T8 lamps?

You need to match the specification for the T8 lamps in question with the ballast. There are some times form factor issues and other times the specific requirements for the lamp in question.


Can you use T12 lamp holders with T8 lamps when you change to T8 ballast?

Absolutely. Only you need connect together two wires coming from each lamp holder (shunt).


What is the three types of hot-cathode fluorescent lamps?

The three types of hot-cathode fluorescent lamps are T12, T8, and T5. T12 lamps are the oldest and largest, T8 lamps are more energy-efficient and commonly used in commercial applications, and T5 lamps are the smallest and most efficient, often used in task lighting or compact installations.


Can you replace t8 bulb in fixture now using t12 bulb?

Yes a T12 lamp socket will take a T8 tube. The T8 tube will not operate. The T8 ballast is an electronic ballast where as the T12 ballast is a magnetic type. If you are changing over fluorescent fixtures to the smaller T8 lamps then the ballast has to be changed and the end sockets have to be rewired. The schematic on how to do the rewire is on the electronic ballast's label.


Difference between T12 and T8 fluorescent bulbs?

A T8 lamp can be retro fitted into a T12 fixture by replacing the T12 ballast with a T8 ballast. The end sockets also have to be rewired in the retrofit as the wiring from the electronic ballast to the sockets is completely different.


What is fuse 10 DRL?

DRL stands for Daytime Running Lamps.


What are the differences between LED tube T5 and T8?

LED tube T8 is much coarser than the LED tube T5 T8 is about 3 cm in diameter ,the diameter of T5 is about 1.5 cm. LED tube T8 Power : 36W (120 centimeters ) 30W (100 centimeters ) 18W (60 centimeters ) LED tube T5 Power : 28W (110 centimeters ) 21w (88 centimeters ) 14W (55 centimeters ) 8W (30 centimeters ) The distinction between T8 and T5 LED tube lamps, and their advantages and disadvantages : The difference between T8 and T5 is the thickness , T8 circumference is 8 cm , T5 circumference is 5 cm . The LED tube T5 has less light decay, longer life, but the lower electro-optic efficiency (the emitted light consuming 1W power ). The LED tube T8 has the more light fades , shorter life, but the higher electro-optic efficiency (the emitted light consuming 1W power). The diameter of LED tube T8 is 24MM LED tube T5 is 16MM in diameter Regular LED tube T8 diameter is 1 inch , 1 inch = 25.4mm, 25.4mm multiply 3.14 = 80mm = 8cm, ie 8 cm .LED tube T5 is 5cm


Is a T8 ballast and T8 bulb more efficient then a T12 ballast and a T8 bulb?

In a T* ballast and T8 bulb more energy efficient then a T12 ballast and a T8 bulb? A:Depends on the CURRENT through the tube. When the Tube is run at 100% of rating, The T12 Takes more CURRENT to give a certain Brightness. Because the surface of the T8 is closer to the ion stream through the tube, it takes less CURRENT to light up the T8 to the same brightness. However, IF you use a T12 in a T8 ballast, you will get LESS CURRENT through the tube, and LESS POWER consumed ALONG with LESS Light.


How do you find T8 sec x cos x?

If cos(x) = 0 then the expression is undefined. Otherwise, it is T8.


What does br40 mean when it refers to a halogen light bulb?

BR stands for Bulk Reflector, that are traditionally for incandescent reflector lamps, not halogen Par lamps, which mean Parabolic Aluminized Reflector.


What can one use CFL lamps for?

CFL stands for Compact Fluorescent Lamp, and they are an energy-efficient alternative to incandescent bulbs. CFL lamps can be used to replace these bulbs, and they can be placed both indoors and outdoors.


What ailment do SAD lamps help with?

The acronym SAD stands for Seasonal Affective Disorder. This is an ailment where one suffers when not exposed to large amounts of sunlight. The lamps are known to help people who suffer from SAD.