Under voltage relay provides a signal (Contacts) when the supplied voltage drops below a preset value.
The way you check to see if an under voltage relay is wired properly is to disconnect the electrical supply. If the device that is connected to the load side of the relay does not start up or energize when the electrical supply is reconnected, then the relay is connected correctly.
The Voltage of the power supply system is rated at its designed value. If this voltage goes down predetermined set value a under voltage relay can sense the change and then trips off the circuit.
For what? Both exist, and are used often.
if you have checked the voltage with a dvom then you need to verify that the power source at the fuel pump relay is correct, if it has the correct voltage pre-relay then your problem is post-relay. if the voltage is not correct pre-relay then simply trace and repair the power source. if the problem is post relay then check the output voltage directly at the relay, if voltage is good trace and repair line from relay to pump. if voltage is not correct then replace the fuel pump relay
Typically, when the coil voltage on a relay is decreased gradually, the relay "hold" will release at a certain voltage. This is usually defined as the Drop-out voltage (defined at some minimum value). Now, in the case of latching relay, the Drop-out voltage is called the Reset voltage.
The fuel pump relay located in the fuse/relay center under the hood.
A voltage monitor relay is in the circuit for one reason. It monitors the incoming voltage to the equipment that it is protecting usually on three phase control panels.The relay monitors the three incoming line voltages and in some relays the voltage to ground (wye connection). If the circuit the relay is protecting looses one of the voltage legs, the circuit will shut down until the problem is rectified. This usually happens if a fuse blows in one of the three phase voltage legs.It also monitors the level of voltage to the circuit. If the voltage drops due to a malfunction in the utility lines the relay will trip and take the protected circuit off line. The voltages can be set to trip at any under or over voltage usually by set point controls on the front of the voltage monitoring relay.
under internal fault conditions , CT primary current produces steep insrease in voltage across the relay. This will exceed the burden 3kv normally designed as per. To get protected from the voltage, metrosil is connected across the relay , to drop the voltage.
The voltage for a potential relay will depend on the circuit that the relay is installed in. The relay can be made for low voltages (5v) to higher voltages (440.)
ocr-over current relay(senses the over current in the circuits) efr-earth fault relay uvr-under voltage relay