Best Answer

A cable tray is a rigid structure to support electric cables.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

10y ago

A cable tray is used to support and enclose electric cables as an alternative to an open wiring or electrical conduit system. They are commonly used in commercial and industrial construction.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is a cable tray?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Can instrument tubing be ran in cable tray?

you need cable tray rated wire to use in a cable try a cable tray is basically open to air so the current rating of the wire doesnt need to be reduced if you have more than 4 conductors cable tray rated tubing is fine( temperature flammability) steel or copper is fine.


What is min vertical distance between data cables tray and low voltage cable tray?

Actually, a data cable tray is a low voltage cable tray also. Data systems are accepted as low voltage systems. Ordinary two data cables do not form any magnetic disturbance to each other. So for an ordinary situation no vertical or horizantal distance required.


How can you lay earthing strip on cable tray?

no use laying an earthing strip in a cable tray better tap both the ends of the earthing wire to the trunking,it will save your wire also,or lay out a cable in the other trunking where you have low voltage wire running in.


How do you calculate armoured cable cross-sectional area?

For electrical purposes the formula for calculating the circular-mil area of a circular wire is very simple. A = D squared, Area equals diameter of the cable or wire squared. This calculation is needed when pulling cables into a cable tray so as not to overfill the tray. Over filling a cable tray will build up a heat from the cables if proper ventilation between the cables is not maintained.


Can RTD Cable and Thermocouple cable shall be laid in a common cable tray?

YesYou should be careful with power cables nearby and make sure they are shieldedwww.peaksensors.co.uk

Related questions

Top Quality Cable Tray?

Channel and Tray is the best cable tray manufacturer in the UK


What is a perforated cable tray?

Its a tray that can carry like ladders.


What is nema ve1 and nema ve2?

They are both cable tray standards. NEMA VE-1 deals with the manufacturing of cable tray and NEMA VE-2 deals with the installation of cable tray.


Can instrument tubing be ran in cable tray?

you need cable tray rated wire to use in a cable try a cable tray is basically open to air so the current rating of the wire doesnt need to be reduced if you have more than 4 conductors cable tray rated tubing is fine( temperature flammability) steel or copper is fine.


What is coupler plate for cable tray?

To join the pair of cable trays.


Is stacking of cables in cable tray permitted?

See NEC Article 392. It depends on the voltage, conductor size and the type of cable tray selected.


What is min vertical distance between data cables tray and low voltage cable tray?

Actually, a data cable tray is a low voltage cable tray also. Data systems are accepted as low voltage systems. Ordinary two data cables do not form any magnetic disturbance to each other. So for an ordinary situation no vertical or horizantal distance required.


Where can you find 600mm stainless steel ladder cable tray?

In a shop


How can you lay earthing strip on cable tray?

no use laying an earthing strip in a cable tray better tap both the ends of the earthing wire to the trunking,it will save your wire also,or lay out a cable in the other trunking where you have low voltage wire running in.


How do you calculate armoured cable cross-sectional area?

For electrical purposes the formula for calculating the circular-mil area of a circular wire is very simple. A = D squared, Area equals diameter of the cable or wire squared. This calculation is needed when pulling cables into a cable tray so as not to overfill the tray. Over filling a cable tray will build up a heat from the cables if proper ventilation between the cables is not maintained.


What does Nos stand for in unit of measure of cable tray material?

Not Otherwise Specified


Can RTD Cable and Thermocouple cable shall be laid in a common cable tray?

YesYou should be careful with power cables nearby and make sure they are shieldedwww.peaksensors.co.uk