Want this question answered?
chemicals
The effect of pH change due to sterilization is that it cold altered the media
This is the mandatory sterilization of abnormal or undesirable people.
This is the mandatory sterilization of abnormal or undesirable women.
Direct sterilization is the destruction of a normal functioning, healthy organ to prevent future conception of children. There are two methods of direct sterilization; a male vasectomy and the ligation of the fallopian tubes of a woman.
Yes. Chemical sterilization and cold sterilization are the same thing.
cold sterilization is used to sterilize instruments such as plastics
Cold sterilization is a process in which sterilization is carry out at low temperature with the help of chemicals, radiations, membranes and all other means excluding high temperature. Ionizing radiation such as x-rays,gamma rays and cosmic rays, cause no appreciable increase in temperature in this method ,it is referred as cold sterilization
chemicals
cold sterilization can and is done in a soak of Cidex solution (glutaraldehyde) in the medical field. Sterilization can be done with steam, gas, and solutions like Cidex.
The effect of pH change due to sterilization is that it cold altered the media
Gluteraldehyde (is toxic), Alcohol can be used as well as Chlorhexadine.
Many products are used for cold sterilisation (i.e. liquid chimical disinfection), with different properties
BACTERICIDAL
Cold sterilization, where the instruments are put in a chemical solution, and it takes around 12 hours for them to become sterilized. Heated sterilization, which is done in an autoclave, under high heat and high pressure. It only takes a few minutes for the instruments to be sterilized.
Cold sterilization is not radiation sterilization. Cold sterilization is a chemical sterilization. * Cold (chemical) sterilization used properly. Effective and proper use of cold sterilization is dependent on many factors including: ** The use of chemicals classified as "sterilants". Those classified only as "disinfectants" are not adequate. ** The physical properties of the item being sterilized. It must be relatively smooth, impervious to moisture, and be of a shape that permits all surfaces to be exposed to the sterilant. ** Adequate exposure to all surfaces, both interior and exterior. Tubing must be completely filled and the materials to be sterilized must be clean and arranged in the sterilant to assure total immersion. The items being sterilized must be exposed to the sterilant for the prescribed period of time. ** Use of efficacious solutions: The sterilant solution must be clean and fresh. Most sterilants come in solutions consisting of two parts that when added together form what is referred to as an "activated" solution. The shelf life of activated solutions is indicated in the instructions for commercial products. Generally, this is from one to four weeks. ** Rinse instruments, implants, and tubing (both inside and out) should be rinsed with sterile saline or sterile water prior to use to avoid tissue damage.
This is a procedure of sterilization using a gas.