Want this question answered?
Symmetrical components are a good way to represent out-of balance currents in 3-phase power supplies. In general an unbalanced set of currents in a 3-phase system can be represented by three compents, which are an in-sequence component, an out-of-sequence (rotating oppositely) component, and a zero-sequence component. At a high-power substation there would be meters for all three components of the current. When the currents are perfectly balanced only the positive sequence current would be non-zero.
Interphase## G1SG2ProphasePrometaphaseMetaphaseAnaphaseTelophaseMitosisCytokinesis
G2
G1 phase is when cell growth occurs
Mitosis is a phase of the cell cycle. It occurs after the G2 phase.
Inter phase including G1, S, G2 and then M phase.
a red giant
The symbol of phase sequence is RYB
The order in which the voltage of the coil reaches to the maximum value is called the Phase Sequence.POSITIVE PHASE SEQUENCE: If the coil is rotated in anticlockwise direction, the phase sequence will be Positive Phase Sequence, i.e., R-Y-B or A-B-C.NEGATIVE PHASE SEQUENCE: If the coil is rotated in clockwise direction, the phase sequence is called Negative Phase Sequence, i.e., R-B-Y or A-C-B.NOTE: Phase Sequence is of great importance in parallel operation of three phase transformers and alternators.
How Negative phase sequence relay work
Negative Phase Sequence is Phenomena generally found in motors,the formula for positive phase sequence is : Ip= Ir + a * Iy + a^2*Ibthe formula for negative phase sequence is : In= Ir + a ^2* Iy + a*IbAs the name suggest the sequence of current or the mmf is in reverse order, a reverse order current in stator will produce a reverse order mmf, now this reverse order mmf is rotating in direction opposite to the rotor of the motor, thus the mmf cut is very high and so current induced in stator is considerably high; as for normal mmf it is in direction of rotor so mmf cut is very small thus current induced is very small.this high current in your rotor leads to overheating of your motor and finally burning of your windings.CommentNegative phase sequence is not 'generally found in motors'. But one of the effects of negative phase sequence would be to cause a three-phase motor to reverse direction.
Symmetrical components are a good way to represent out-of balance currents in 3-phase power supplies. In general an unbalanced set of currents in a 3-phase system can be represented by three compents, which are an in-sequence component, an out-of-sequence (rotating oppositely) component, and a zero-sequence component. At a high-power substation there would be meters for all three components of the current. When the currents are perfectly balanced only the positive sequence current would be non-zero.
g3
Interphase## G1SG2ProphasePrometaphaseMetaphaseAnaphaseTelophaseMitosisCytokinesis
gas
If you reinstall a three-phase motor with two of the supply conductors interchanged, then the resulting negative phase sequence will cause the motor to run in reverse.
motor is designed to operate in forward and reverse direction for the purpose of elevator. Phase sequence protection is not required.