answersLogoWhite

0


Best Answer

This question cannot be answered as asked. you would need to know also the voltage and phasing.

Assuming we are dealing with 120-volt, single phase, 11,500 watts would be 55-running amps.

Assuming we are dealing 208-volts, three phase, 11,500 watts would be 32 running amps

and assuming we are dealing with 250-volt three phase, 11,500 watts would be 26.5 running amps.

I hope I have answered your question.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is circuit breaker rating when electric load of a machine is 11.5 kW?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is the proper ampere rating of circuit breaker for electric arc welder?

The proper ampere rating of a circuit breaker for an electric arc welder depends on the arc welder. Each is different. Look at the nameplate on the arc welder and choose the circuit breaker and wiring accordingly.


Can you replace a 2000 A Circuit breaker with 3150 A rating?

No.


Why are electric ranges wired to separate circuit breaker?

As a range is a high current device, the electrical code stipulates that it has to have its own breaker. The breaker protects the wire feeder. An electric range breaker is set to trip at 40 amps. Using a smaller wire that #8 is not allowed as their ratings are below that of the #8 wire. #10 wire rating is 30 amps, #12 wire rating is 20 amps, and #14 wire rating is 15 amps.


What are the breaker ampere trip ratings?

The ampere frame rating for a circuit breaker designates how the circuit breaker should be configured. It also states the trip unit of the amp.


What is a difference between 10KA and 22KA circuit breakers?

The previous answer is incorrect, and I would advise that user to not give out information if they are going to give completely misguided information. The interrupting rating of a breaker is the maximum current that the breaker is designed to handle, at the breaker's rated voltage, before damage will occur to the breaker. A breaker will trip at FAR LESS than the interrupting rating, but it is extremely dangerous to expose the breaker to any situation where it will have more than the rated interruption current. the breaker is designed for. The reason some breakers are rated at 22kA instead of 10kA is because they typically have far larger conductors hooked up to them, so with the lowered impedance on the circuit there is more of a chance for the breaker to experience a higher fault current at the breaker. So electricians install 22kA breakers to handle the higher "available fault current."

Related questions

What is the proper ampere rating of circuit breaker for electric arc welder?

The proper ampere rating of a circuit breaker for an electric arc welder depends on the arc welder. Each is different. Look at the nameplate on the arc welder and choose the circuit breaker and wiring accordingly.


What circuit breaker rating do you need for a 3 phase electric motor?

The circuit breaker is sized to the full load amps of the motor times 250%.


Will a circuit breaker give off less amperage?

A circuit breaker does not give off amperage. A circuit breaker allows a flow of current up to the rating of the breaker. Any current higher than that of the breaker's rating will open the breaker's contacts and stop the flow of current.


Can you replace a 2000 A Circuit breaker with 3150 A rating?

No.


How many ampacity rating do a circuit breaker need for the general purpose circuit?

Usually a 15 or 20 amp breaker is sufficient


Why are electric ranges wired to separate circuit breaker?

As a range is a high current device, the electrical code stipulates that it has to have its own breaker. The breaker protects the wire feeder. An electric range breaker is set to trip at 40 amps. Using a smaller wire that #8 is not allowed as their ratings are below that of the #8 wire. #10 wire rating is 30 amps, #12 wire rating is 20 amps, and #14 wire rating is 15 amps.


What are the breaker ampere trip ratings?

The ampere frame rating for a circuit breaker designates how the circuit breaker should be configured. It also states the trip unit of the amp.


How much amperage does a gas clothes dryer draw?

Check the nameplate rating on the door or door frame of your washer, it should tell you the amp rating or the kw rating of the machine. If it only has the KW rating of the machine, simply divide the KW rating by the voltage of the receptacle and it'll give you the current (ampere) rating. Typically, a modern washing machine will draw approximately 7-12 amps. However, anticipate a higher amperage when starting the machine as the machine will draw 1.5X the rated current to start the machine (starting current). Regardless of the amp rating, the NFPA-70 (National Electrical Code) requiresa 20 Amp fuse or circuit breaker; and the circuit for the washing machine must be on its own, dedicated circuit.


How close can a washing machine be to an electric circuit box?

dont try to run one on a 100 ft cord . check the voltage. it must be with in 10 % of the rating of the machine


What size amp circuit breaker should be used for a gas dryer?

Typical residential electric dryers are on 30 amp circuits, which means 10 gage copper wire. The circuit breaker should match the dryer cord rating, generally 30 amps.


What size amp circuit breaker should be used for a pool light?

The pool light is usually on a 15 amp circuit. The breaker feeding this circuit must have a GFCI rating.


Rating of a 3 pole circuit breaker is the same for each conductor?

Yes, the rating of a 3 pole circuit breaker is the same for each conductor that is connected to it. A three pole breaker rated at 30 amps will have 3 #10 wires from it that connect to the load.