When the curent Is in the secundary for the highervalues Ip in the primary coil are not equal proportional than for the lower curent. Is/Ip for lower values is for exemple 100 Is/Ip for higher values are for exemple 70

The reason is the magnetique flux saturation in the closed iron core.

Roger

User Avatar

Wiki User

16y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

Transformer saturation is when its primary is run overvoltage and there is no load current drawn from the secondary.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is saturation in current transformer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What causes saturation in a welding transformer?

what causes saturation in welding machine


How is transformer saturation avoided in class B push pull amplifier operation?

In class B amplifier no DC biasing required, thus lack of of DC current in inpunt and load, saturation of core avoided


Why transformers take high input current at start?

Inrush current is a result of core saturation. The magnetic flux in the core of a transformer is 90 degrees out of phase with the voltage. Ideally the transformer switching device will be closed at a peak voltage, and the transformer core will have no residual flux from the last close. If this occurs, the flux in the core in the first cycle will be no larger than it normally would be. If the switching device closes at a zero voltage, or there is some residual flux, the transformer's core will be driven into partial saturation within the first cycle, unless it has been oversized to prevent saturation. Decreasing the applied voltage at energization will keep this from occuring. One method is to use pre-insertion resistors which cause a voltage drop to the transformer that is significant enough to prevent saturation within the first few cycles, and then they are removed. Another method is to de-engerize the transformer core, and close at voltage peaks only (controlled closing).


How is current controlled in welding transformer?

in welding machine, the transformer used is basically a current transforrmer. so by changing the tap of secondary side of transformer, we can increase or decrease the current in the transformer.


What is principle of Current transformer?

why does have to short-circuit secondary wire of current transformer ?

Related questions

What type of current must be used with a transformer?

DC current cannot be used in a transformer only AC will work. A transformer needs the continual build and collapse of the magnetic field to keep the iron core from reaching saturation. Only alternating current will transfer power through a transformer.


What causes saturation in a welding transformer?

what causes saturation in welding machine


What has the author David John Corns written?

David John Corns has written: 'Current transformer saturation and the effect on protective devices'


How is transformer saturation avoided in class B push pull amplifier operation?

In class B amplifier no DC biasing required, thus lack of of DC current in inpunt and load, saturation of core avoided


What will happen if transformer are connected to dc supply?

It will get core saturation


Why transformers take high input current at start?

Inrush current is a result of core saturation. The magnetic flux in the core of a transformer is 90 degrees out of phase with the voltage. Ideally the transformer switching device will be closed at a peak voltage, and the transformer core will have no residual flux from the last close. If this occurs, the flux in the core in the first cycle will be no larger than it normally would be. If the switching device closes at a zero voltage, or there is some residual flux, the transformer's core will be driven into partial saturation within the first cycle, unless it has been oversized to prevent saturation. Decreasing the applied voltage at energization will keep this from occuring. One method is to use pre-insertion resistors which cause a voltage drop to the transformer that is significant enough to prevent saturation within the first few cycles, and then they are removed. Another method is to de-engerize the transformer core, and close at voltage peaks only (controlled closing).


Reverse saturation current of Ge diode?

Reverse saturation current of germanium diodeThe current that exists under reverse bias conditions is called the reverse saturation current. Reverse saturation current of the germanium diode is typically 1 micro ampere or 10-6 a.At a fixed temperature, the reverse saturation current of a diode increases with increase in applied reverse bias. In reverse bias region the reverse saturation current also varies with the temperature.


What is the affect of core saturation upon turns ratio of a transformer?

Electrical Engineering


What is a c200 current transformer?

This is a class of current transformers, and is a fairly low class. This has to do with what kind of burden can be placed on the secondary. A general rule is a C200 current transformer can supply ~200 volts at full ratio to its' secondary. If the burden (the CT resistance + cable resistance + relay or instrument resistance) times the maximum expected current is higher than 200 volts, the CT is likely to saturate. During multiple fault events, a CT may keep some magnetizing current causing CT saturation to be higher on a reclose event. Typically CT's are sized and their ratios are chosen to minimize saturation when feasible.


What is saturation region in general?

Saturation region is one in which the output current is independent of the input and remains almost constant. Hence, MOSFETs in saturation are modeled as current sources( whose current is independent of voltage across it)


How is current controlled in welding transformer?

in welding machine, the transformer used is basically a current transforrmer. so by changing the tap of secondary side of transformer, we can increase or decrease the current in the transformer.


What is principle of Current transformer?