The static resistance which is calculated from the static ch. of doide is the dc resistance offered by the diode. dynamic ch. of the diode describes the diode's behavior when the applied voltage is fluctuating,or ac, thus the dynamic resistace is simply the ac resistance offered by the diode.
akhil gopal
punnapra
there is no such thing as static var cenerator but if you meant static var generator then the difference is the same. it is one in the same thing, a combination or inductance and capitance to generate either reactive inductance or capacitive reactance.
Inductive reactance.
Inductive reactance does NOT have it own sign or symbol. Rather, it uses Ohms as a quantifier. But Capacitive reactance ALSO uses Ohms as a quantifier. Fortunately, 1 Ohm of Inductive reactance is cancelled by 1 Ohm of Capacitive reactance at the same frequency of measurement.
reactance relay is used for distance protection of the transmission line....
Xc(capacitive reactance) = 1/(2piFC)XL(inductive reactance) = 2piFLWhere pi=3.14etc.,F=frequency and C and L are capacitance and inductance.Please pardon lack of proper symbology.
there is no such thing as static var cenerator but if you meant static var generator then the difference is the same. it is one in the same thing, a combination or inductance and capitance to generate either reactive inductance or capacitive reactance.
I don't think there is a static economy. The economy is dyanmic. Things can always change. If the government uses up less resources there would me more for the private sector to use. Government doesn't produce anything. It can only take it from one person and then give it to another person after the cost of all the red tape.
Inductive reactance, as well as capacitive reactance, is measured in ohms.
Dyanmic memory allocation ... we can easily manipulate the data
Inductive reactance.
The reciprocal of reactance is susceptance, expressed in siemens.
The symbol for inductive reactance is XL.
for inductor, reactance XL = 2*pi* f *L, if frequency doubles then reactance increase. But for capacitor, reactance Xc = 1/(2*pi*f*C). In this case if frequency doubles the reactance decrease.
The overall reactance of the armature winding is the sum of its leakage reactance plus fictitious reactance, which is known as synchronous reactance (Xs).Xs=XL+Xarwhere XL and Xar are in Ω/phase. Therefore, Xs is in Ω/phase.The impedance of armature winding is obtained by combining its resistance and its synchronous reactance.
Inductive reactance does NOT have it own sign or symbol. Rather, it uses Ohms as a quantifier. But Capacitive reactance ALSO uses Ohms as a quantifier. Fortunately, 1 Ohm of Inductive reactance is cancelled by 1 Ohm of Capacitive reactance at the same frequency of measurement.
Because it is. Capacitive reactance is a form of resistance, along with inductive reactance. All are measured in ohms.
Resistance is a concept used for DC. the current through a resistance is in phase with the applied voltage Reactance is used for AC the current through a inductive reactance lags the applied voltage by 90 degrees. the current through capacitive reactance leads the applied voltage by 90 degrees. the net reactance is the difference between inductive and capacitive reactance