answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What is sweep time in an oscilloscope?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What the function of time base in an oscilloscope?

The time base of an oscilloscope is used to increase or decrease the time per division value on the Y-axis ranging from few tens of seconds to micro seconds to nanoseconds used for microwave signals.If you increase the time base of an oscilloscope lesser and lesser part of the signal will be present in one division of the Y-axis. Setting the time base to a proper value will enable you to see high frequency signals clearly otherwise each cycle of the signal would be indistinguishable from the other huehue


What is sweep speed error?

It is the ratio of the difference in slope at beggining and end of sweep to initial value of sweep.This error is due to deviation fron linearity.The important requirement of sweep is that it must vary linearly with time.


Can you measure current with an oscilloscope?

Oscilloscopes only measure voltage over time. Current cannot be measured with an Oscilloscope directly, but can be measured indirectly. Measure the voltage across a known load and calculate the current.


What is different between analog Oscilloscope and digital Oscilloscope?

As with analog ( Dial) watches versus Digital clocks- there are two different types of presentation. The Analog Oscilloscope is more properly called a Cathode Ray oscilloscope as it uses a specialized CRT ( Cathode Ray tube) the Digital creates and displays its graphics in a digital fashion. They do not need a warm-up time as they do not use vacuum tubes. Storage oscilloscopes, which have a time-lapse feature most intriguing and a memory bank, can be and have been made in both the analog and the digital configurations. the German Hameg company marketed both types.


What is Time.DIV on the oscilloscope?

Time . Division.Varies how the divisions on the time scale are applied.Changes the speed of the sweep.Each division is equivalent to 1millisecond, 5 millisecond, 10 millisecond etc.

Related questions

What units is the horizontal sweep of an oscilloscope rated in?

The horizontal sweep of an oscilloscope is in time per division or seconds per division.


What do you mean by dual channel of cathode ray oscilloscope?

An oscilloscope with 2 vertical inputs that are multiplexed to the CRT, either by chopping them together on every sweep or alternating between them on every other sweep. Some oscilloscopes also support a differential mode where the 2 inputs are subtracted to produce a single combined signal.


How a Cathode Ray Oscilloscope is used to measure Period?

period are measued in oscilloscope by using or calculating time division


What is meant by a computer oscilloscope?

A computer oscilloscope is used in computer diagnostics, where the oscilloscope measures voltages at different points of microchips at different points of time in order to find the broken part.


What is the time base of an oscilloscope?

This is the internal circuit that causes the horizontal movement of the electron beam across the screen of the oscilloscope. It can be adjusted to vary the time taken for the beam to move across the screen.


Is the oscilloscope trace movement across the CRT related to time?

Yes


How do you read the oscilloscope?

Time (horizontal scale) versus Amplitude (vertical scale).


How does an oscilloscope measure time?

An oscilloscope does not measure time. It is used to plot signals which are displayed as a change of voltage against (or with reference to) a change in time. To do this, the scope has to have something inside it to generate a "time tick" or otherwise provide a time reference. We usually find that a crystal oscillator is doing that job.


What precautionary steps have to be taken when using an oscilloscope?

Beware using ground clips for high speed measurements.Beware of oscilloscope bandwidth limitations.Ensure the correct triggering.Use the right oscilloscope probe.Remember to calibrate the oscilloscope probe.Beware using ground clips for high speed measurements.Beware of oscilloscope bandwidth limitations.Ensure the correct triggering.Use the right oscilloscope probe.Remember to calibrate the oscilloscope probe.


How is frequency of an electromagnetic wave measured?

The wave is amplified electronically and applied to either an oscilloscope ,where the trace is drawn on a calibrated graticule using a known timebase sweep, or it is applied to an electronic timer that counts the time for one complete cycle of the unknown wave and displays the result digitally as Hertz by means of a frequency meter.


Can digital oscilloscope do spectrum analysis?

A: absolutely but never in real time. That is the nature of the beast


Why does an oscilloscope have 2 channels?

because of the convenience to compare two signals at same time