It makes no difference as to what system is being monitored. The meter itself has to be accurate because it comes under the government's weights and measures department. Meters in the field are checked if the consumer thinks there is a problem with their billing. Before a meter is put into service they are all checked for accuracy by an independent agency.
Single phase connection has 1 phase wire and a neutral wire. Another wire for protective earth. In three phase system, motor can be connected in star or delta. Most AC induction motors are in Delta. Power distribution system is generally 3 phase 4 wire. Transmission system is 3 phase high voltage. Industry uses 3 phase system, where as 1 phase is for domestic, commercial applications. Both 1 and 3 phase system has a frequency. It is either 50 Hz or 60 Hz, depending upon the country or region.
A two-phase system is archaic and you are unlikely to find it in use anywhere these days, so it is mainly of historical interest. A two-phase, three-wire system, consists of two phase voltages, displaced from each other by 90 electrical degrees, and a phase voltage which is 1.414 x phase voltage.A three-phase system consists of three phase voltages which are displaced from each other by 120 electrical degrees. In the case of a three-phase, three-wire, system, the line voltages are numerically equal to the phase voltages; in the case of a three-phase, four-wire, system, the line voltages are 1.732 x phase voltage.
5000 volt
A two-phase a.c. system is an archaic system, in which two phase voltages are generated 90 electrical degrees apart. It has nothing whatsoever to do with the US 'split phase' system that supplies North American homes. A two-phase system can be a four-wire system, or a three-wire system, and was useful because, unlike a single-phase system, it could create naturally rotating magnetic fields in induction motors. It has long been superseded by the three-phase system.
NO! The voltages available in the 3-phase system are 480 (if you wire phase to phase) and 277 (if you wire phase to neutral) Don't try it!
of all of dem 3 phase 3 wire is most economical as it uses less conductor dan in 4 wire system, 3 phase 3 wire is used in transmission and 4 wire in distribution as it has 3 live and one neutral wire. 3 phase needs lesser conductor size than 2 phase 4 wire for the same power. 3 wire dc feeder is more economical than 2 wire dc feeder for the same power. that was all i cud get..... hope u find it a lil helpful.
Single phase connection has 1 phase wire and a neutral wire. Another wire for protective earth. In three phase system, motor can be connected in star or delta. Most AC induction motors are in Delta. Power distribution system is generally 3 phase 4 wire. Transmission system is 3 phase high voltage. Industry uses 3 phase system, where as 1 phase is for domestic, commercial applications. Both 1 and 3 phase system has a frequency. It is either 50 Hz or 60 Hz, depending upon the country or region.
A two-phase system is archaic and you are unlikely to find it in use anywhere these days, so it is mainly of historical interest. A two-phase, three-wire system, consists of two phase voltages, displaced from each other by 90 electrical degrees, and a phase voltage which is 1.414 x phase voltage.A three-phase system consists of three phase voltages which are displaced from each other by 120 electrical degrees. In the case of a three-phase, three-wire, system, the line voltages are numerically equal to the phase voltages; in the case of a three-phase, four-wire, system, the line voltages are 1.732 x phase voltage.
5000 volt
no
It depends on the type of three-phase system. If it's a three-wire system, then the phase voltage is numerically equal to the line voltage. If it's a four-wire system, then the phase voltage is numerically equal to the line voltage divided by 1.732 -in your example, this works out to be 5.77 V.
Three-wire transmission is used on balanced three-phase systems when the current is known to be equal in all three phases, for example when supplying a three-phase motor. A fourth neutral wire is used when the system is liable to have unequal currents or when multiple single-phase supplies are connected to it.
A two-phase a.c. system is an archaic system, in which two phase voltages are generated 90 electrical degrees apart. It has nothing whatsoever to do with the US 'split phase' system that supplies North American homes. A two-phase system can be a four-wire system, or a three-wire system, and was useful because, unlike a single-phase system, it could create naturally rotating magnetic fields in induction motors. It has long been superseded by the three-phase system.
NO! The voltages available in the 3-phase system are 480 (if you wire phase to phase) and 277 (if you wire phase to neutral) Don't try it!
Polyphase systems are used because they allow the efficient transmission of electric power, in terms of power transmitted per kilogram of wire. Polyphase systems with more than three phases are very uncommon.
High or "wild" leg phase to ground.
The neutral.