the sea erodes the stack to such a point until the wasn't enough suport and the roof colapsed making the arch become a stack.
It allows the drains to flow freely and the stench of the sewer to be sent to the highest point in the roof. That is why p-traps are installed, so the sewer gasses go to the roof vents and not through the water in the traps.
Only if you want to smell the fumes all the time. Code says it should be through the roof or above the edge of the roof.
If you are talking about a roof water drain pipe to sewer it is illegal. If you are talking about a sink drain pipe well that is where they all connect to so yea.
A stack vent is is the extension of a soil or waste stack above the highest horizontal drain connected to the plumbing stack Vent stack a vertical vent pipe extending through more then two stories which is then connected to a stck vent or is otherwise extended throgh the roof, installed primarily for the purpose of providing circulation of air to and away from any part of the drainage system
By removing foul sewer fumes and venting them to the outside air nomally through the vent terminal knowing warm air rises
Very rarely will a roof sewer vent need to be cleaned. On the occasion that you need to remove debris or a nest, the best way is to try a shop vac. Then you could try a hose to clear any other items down thru the drain pipe. These methods should be adequate to remove 99% of the blockages. Never try to snake a roof vent! There are too many dangers and problems that may occur from trying to do so.
the sea erodes the stack to such a point until the wasn't enough suport and the roof colapsed making the arch become a stack.
It's on the roof of the gift shop, go to the HQ and talk to G and he will give you the key to the roof then its on the sewer drain on the roof! ☺
It allows the drains to flow freely and the stench of the sewer to be sent to the highest point in the roof. That is why p-traps are installed, so the sewer gasses go to the roof vents and not through the water in the traps.
A vent Terminal and depending if the roof is strictly for weather protection it terminates about 24" above the roof. If the roof area is for people then it is 7 ft above the roofing surface.
1-Clear the obstruction from the vent or drain pipe 2-Be sure the vent is properly sized and graded up towards the penetration of the roof, or where it ties into the vent stack.
Yes. The roof vent is usally located on the roof. If the vent is clogged, it can create numerous issues and prevent your plumbing system from working properly.
Yes
Only if you want to smell the fumes all the time. Code says it should be through the roof or above the edge of the roof.
They Shouldn't be If the roof is weather protection only then the vent terminal should be 2ft if the roof is used for promenade Then it should be 7 ft
Don't make the mistake of stacking it up there. That is a dangerous proposal. Use the sheeting as you hand it up.