It might be less than (10.33/sp. gravity) m
In boiler feed pumps usually the discharge pressure is 20 to 30 times tie suction Pressure so to protect the pump balancing line is given from discharge to suction.
The maximum distance will be relative to the efficiency of the pump and the rated flow of the pump vs the size of the suction hose. The more efficient the pump, the more vacuum it can draw, and the larger the suction hose in relation to the flow rating of the pump the farther you can move the pump away from the water. The manufacturer of the pump will have charts that will help you properly size and set up your pump for optimum performance.
what is th different between end suction pump and singl stage pump and multistage pump
to equalizing the pr. and to suck air that helps the priming.
A single suction pump having its suction nozzle on the opposite side of the casing from the stuffing box and having the face of the suction nozzle perpendicular to the longitudinal axis of the shaft
It is common practice to specify the pump suction line one size larger than the pump discharge line in order to increase the Net Positive Suction Head available (NPSHA) to the pump. A smaller suction line the same pipe size as the discharge line would result in more pressure drop in the suction line and reduce the amount of head available to the suction side of the pump. This in turn would result in an operating point closer to cavitation of the pump.
lenth
Between compressor suction and reversing valve,also called true suction.
Between compressor suction and reversing valve,also called true suction.
In boiler feed pumps usually the discharge pressure is 20 to 30 times tie suction Pressure so to protect the pump balancing line is given from discharge to suction.
this is overhang centrifugal pump . the suction drum level , suction strainer and suction pipings were all checked and found OK
between the comp and the reversing valve
The maximum distance will be relative to the efficiency of the pump and the rated flow of the pump vs the size of the suction hose. The more efficient the pump, the more vacuum it can draw, and the larger the suction hose in relation to the flow rating of the pump the farther you can move the pump away from the water. The manufacturer of the pump will have charts that will help you properly size and set up your pump for optimum performance.
between the comp and the reversing valve
Suction lift is only negative. Suction head is positive or negative.Suction head is the distance between the surface of the liquid being pumped and the centerline of the pump. It can be positive or negative, and it can be affected by pressure or vacuum on the surface of the fluid. A negative suction head is also called suction lift.Example 1: A D/A under 15 psig is set 20 feet above the feed pump the effective suction head is 54 feet. (15 psig is equivalent to 34 feet of water).Example 2: A Condenser hotwell under 28 inches of vacuum (Hg) is set 16 feet above the suction of a propeller pump. The effective suction head (lift) is -15 feet.* (28"Hg = - 31 feet of water)Example 3: A sump pump is set 4 feet below the surface of the well. The effective suction head is 4 feet.*Note: Suction lift is only effective to a maximum of 21 feet, and 15 feet for hot water depending on temperature and pump slip.
If everything is functioning as it should the pump should push all the air out of the system. If there is consistently air in the system it is probably seeping in on the suction side of your pump, which will shorten the life of your pump. Check your suction line for leaks.
what is th different between end suction pump and singl stage pump and multistage pump