You probably need a 5hp or 7hp motor. Look for HP rating o the 3 phase motor and select the same for single phase. 3 phase has same power but is more efficient at electricity use. Also consider a 3 phase converter. It allows a 3 phase motor to run on single phase service.
In electrical terms a three phase compressor is a compressor that is driven with a three phase motor. There are compressors that have three pressure heads. The three heads boost the pressure up in higher increments but these are referred to as three stage compressors.
C = common S= start R= run
If your three phase motor runs backward, you have two phases swapped. double check a, b and c phase to find which ones are misplaced.
Depending on who does the work it could be less expensive than getting a different air conditioner. The compressor will also need a capacitor and some rewiring. The old unit could have a 3 phase blower motor also which could run the price up even more. Although the changes can be made, the warranty at best will probably be a one year warranty and a new unit could have a 5-10 year warranty.
You can not change it. 440 volt is by design. However you run it with 220 single phase supply, but it would run far lower power.
only way to convert from 3 phase to 240 would be to change the electric motor on the compressor
In electrical terms a three phase compressor is a compressor that is driven with a three phase motor. There are compressors that have three pressure heads. The three heads boost the pressure up in higher increments but these are referred to as three stage compressors.
C = common S= start R= run
I would use a totally enclosed motor.
If your three phase motor runs backward, you have two phases swapped. double check a, b and c phase to find which ones are misplaced.
You will need to install a phase converter or change the motor to single phase. You can find a licensed electrician at www.contraxtor.com
It depends on how, and with what you change them.
no
Depending on who does the work it could be less expensive than getting a different air conditioner. The compressor will also need a capacitor and some rewiring. The old unit could have a 3 phase blower motor also which could run the price up even more. Although the changes can be made, the warranty at best will probably be a one year warranty and a new unit could have a 5-10 year warranty.
Need motor voltage, amperage and phase to give you an anwer.
MOST LIKELY A COMPRESSOR SHORTED TO GROUND IF 3 PHASE. COMPRESSOR START PARTS OR SHORTED COMPRESSOR- SINGLE PHASE. COULD ALSO BE CONDENSER FAN MOTOR OR CAPACITOR ASSUMING IT STARTS WITH THE PRIMARY COMPRESSOR. WITH POWER OFF, CHECK WITH OHMMETER EACH COMPRESSOR LEAD TILL YOU FIND SHORT (LOW RESISTANCE READING). IF THREE PHASE, IT IS POSSIBLE TO REVERSE MOTOR DIRECTION IN AN ATTEMPT TO FREE UP A FROZEN COMPRESSOR (RECIP ONLY, NOT FOR SCROLL IN THAT THEY ARE ROTATION SPECIFIC). ONCE YOU GET IT GOING OR HAVE COMPRESSOR REPLACED, FIND OUT WHAT CAUSED FAILURE AND FIX IT. IT WILL JUST HAPPEN AGAIN IF YOU DON'T. THEY DON'T JUST WEAR OUT IF MAINTAINED PROPERLY. lc
You can not change it. 440 volt is by design. However you run it with 220 single phase supply, but it would run far lower power.