No, and adapters are not needed. What needs to be done in remove the old three blade dryer plug and install a new four blade cord on the dryer.Dryer plug three to fourInstructions should come with the new cord. Open up the electrical access panel on the back of the dryer. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the dryer. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug that connects to where the removed grounding strip attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.
Go to this site http://www.generatorjoe.net/html/nemaplugs.html and tell me what configurations you have and I might be able to help you.
The voltage is 3 x 36 or 108 volts.
The same as in single phase with the same RMS voltage.
6350.8 volts AC rms. The phase to earth voltage is ( square root(3) ) x lower than the phase-phase voltage on a 3 phase system.
All three prong dryer cords should fit all three prong outlets. Dryer and stove plugs are different but as long as someone didn't use one in place of a dryer cord, there isn't a problem.
Under the new electrical code rules three prong dryer cord receptacles and therefore cords are not allowed to be installed. As you are finding out, stores are not carrying them in stock any more. You should consider an upgrade for safety sakes, to a four prong plug cord and change the wall receptacle to a four prong receptacle. There are instructions on how to do this your self on Answers.
Change either the plug or the cord. The fourth prong is another ground. It would be easier to change the cord.
How do the wires connect on a 3 prong electrical cord on the lde8414ace maytag dryer
call an electrician!!!
A qualified electrician should make the change to a dryer connection. The best way to cheaply make the change is to change the power cord on the dryer to the three hole standard.
No. You will no longer be getting the correct voltage to the appliance. It should be replaced before using again.
As far as I know, you can't. It would be safer to have a new outlet installed closer to the dryer.
Dryer plug three to fourOpen up the electrical access panel on the back of the dryer. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the dryer. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug that connects to where the removed grounding strip attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.
If you don't know you should not be doing it because this could be dangerous.
Only if you wanted to fry your hair.for God sake(and yours)buy a new cord to hook up your dryer
I would not recommend trying to use an extension cord for a dryer. the better option is to either buy a longer cord that is properly sized to deal with the extra distance or have an electrician come out and either move the outlet or custom make you a longer cord for your dryer.