A three phase transformer is simply three Transformers so, supplying one phase to a set of three transformers will result in only one phase output. Any loads connected to that transformer that are expecting three phase power will malfunction, and could fail.
Answer
A three-phase transformer is NOT 'three separate single-phase transformers', as suggested in the original answer. It is a single transformer with three primary and secondary phase-windings wound around a common three-limb ('core') or five-limb ('shell') core. If a single-phase supply was applied to one of the three primary windings, then single phase voltages would appear across each of the three secondary windings and the remaining two primary windings. These voltages would not be out of phase with each other.
it would damage because if you try to supply a two phase ,,so the output magnet isn't balance
If one line supplying a 3-phase transformer is disconnected, it leaves 2 wires and the output of the transformer is single-phase.
the necesscity of two three phase transformers operating in parallel are as follows...if the one transformer fails to give supply,then another transformer can be used in parallel and hance,continuity of supply can be maintained.one transformer can be easily take out from the supply for repair & maintanance.if the load on the substation increases beyond the rated values of transformer, then another transformer can be used to share rhe load of the substation.
yes
A single-phase transformer works with a single-phase supply, while a 3-phase transformer is used with a 3-phase supply. A single-phase transformer has 2 wires on the primary and secondary (ignoring taps) while a 3-phase tansformer has 3 or 4 wires on the primary and secondary.
You can go to an electrical supply store and purchase a transformer that will work for youAnswerA single phase supply can be obtained by connecting the load between any pair of line conductors, or between one line conductor and the neutral -depending on the nature of your three-phase supply. The single-phase voltage must match the rated voltage of your warmer, otherwise you must use a transformer.
Yes, you can use three single phase transformers on three phase applications and interconnect them to serve as a single transformer or you could use one single phase transformer fed from two of the three lines in a step down application.
Your question is confusing because you give absolutely no information on the transformer, such as its turns ratio, or any information about the supply voltage. Presumably, though, you are describing a three-phase transformer, as you refer to three wires? Again this is confusing, because you do not describe how you would supply single phase to 'all three wires'!
A Scott transformer converts 3-phase to 2-phase and vice versa, so if you get a Scott transformer it can convert a 2-phase supply into 3-phase for the motor. Caution: the 2-phase supply has to be a genuine 2-phase as defined, with 90 degrees phase between the two phases, and these are extremely uncommon. A Scott transformer CANNOT be used with the split-phase supply found in many US homes which have a 240 v single-phase transformer with the centre earthed and connected to a neutral wire to produce two 120 v circuits.
the necesscity of two three phase transformers operating in parallel are as follows...if the one transformer fails to give supply,then another transformer can be used in parallel and hance,continuity of supply can be maintained.one transformer can be easily take out from the supply for repair & maintanance.if the load on the substation increases beyond the rated values of transformer, then another transformer can be used to share rhe load of the substation.
yes
Your question is rather vague. If you are asking what do you call a group of single-phase transformers, connected to supply three phase, then the answer is a 'three-phase transformer bank'.
Yes
If you want a five-phase supply you need to start with a three-phase supply and a transformer that has 15 symmetrical cores. But why would one need a five-phase supply . . three is enough.
Any where that a three phase supply distribution is needed to operate three phase equipment.
The main application for a core type transformer is to increase voltage from a standard 240v supply up to 415v instead of using a 3 phase supply.
To continuously supply a load of up to 30-V.A at the rated secondary voltage of the transformer.
A single-phase transformer works with a single-phase supply, while a 3-phase transformer is used with a 3-phase supply. A single-phase transformer has 2 wires on the primary and secondary (ignoring taps) while a 3-phase tansformer has 3 or 4 wires on the primary and secondary.
You can go to an electrical supply store and purchase a transformer that will work for youAnswerA single phase supply can be obtained by connecting the load between any pair of line conductors, or between one line conductor and the neutral -depending on the nature of your three-phase supply. The single-phase voltage must match the rated voltage of your warmer, otherwise you must use a transformer.