Best Answer

For moving-iron instrument magnetic field is caused when the current (voltage) passes the fixed circle. When the current (voltage) passes the fixed circle,the two iron plates are magnetized ,rotational torque is resulted, the deflection angle indicate measured current. Because the magnetized polarity is same for AC or DC, moving-iron instrument can be used in AC and DC circuit. For permanent-magnet moving-coil instrument magnetic field is caused by the permanent-magnet, When the DC current passes the moving coil, rotational torque is resulted,so the deflection angle indicate measured DC current. As AC current passes the moving coil ,because inertia of moving parts of meter the deflection angle indicate rotational torque average, but rotational torque average is zero in cycle, moving parts of meter is´t deflec,so permanent-magnet moving-coil instrument only is used in DC circuit.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why are moving iron test instruments not used with DC although they can work in DC?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Is Voltmeter is a moving iron Instrument or moving coil instrument?

If this is a homework related question, you really should consider trying to solve it yourself before looking at this answer. Otherwise, the value of the lesson, and the reinforcement provided by the assignment, will be lost to you.A moving coil measuring instrument has a coil attached to the indicator, surrounded by a magnet.A moving iron measuring instrument has a magnet attached to the indicator, surrounded by a coil.In both cases, the indicator is driven by magnetic torque caused by current flow in the coil.


Why the iron losses absent in short circuit test?

Because a short-circuit test is done at very low voltage to check the transformer windings on their maximum current. The low voltage ensures that the magnetic flux in the transformer's iron core is very low so that the eddy-current losses, usually known as iron losses, are negligible.


Why do you neglect iron loss in transformer during short circuit test?

in short circuit test we apply rated current with the LV side shorted.so the applied voltage will be very low. iron loss depends on the applied voltage.so it is neglected


Explain how a moving iron instrument attraction type operates?

when our instrument is ready to use . We switch on the supply, and E.M.F will induced due to that E.M.F the starting torque will produce in the coil and it will deflect hte needle due to the E.M.F induced in the ckt .. it for A.C. purpose nw we can also use this for dc measurment by reversr this process .when we reverse this process the torque will reversed and the need will change its position due to deflecting torque . so by these we can use it on booth supplyes on A.C. as well as D.C...AnswerAn 'attraction type' moving-iron instrument consist of a coil, through which the test current is passed, and a pivoted soft-iron mass attached to the pointer. The resulting magnetic polarity at the end of the coil nearest the iron mass then induces the opposite magnetic polarity into the part of the iron mass nearest the coil, which is then drawn by attraction towards the coil, deflecting the pointer across a scale.


What does wattmeter indicate in blocked and no load test?

A water meter that says no load test means one thing. The thing that it means is iron loss.

Related questions

Is Voltmeter is a moving iron Instrument or moving coil instrument?

If this is a homework related question, you really should consider trying to solve it yourself before looking at this answer. Otherwise, the value of the lesson, and the reinforcement provided by the assignment, will be lost to you.A moving coil measuring instrument has a coil attached to the indicator, surrounded by a magnet.A moving iron measuring instrument has a magnet attached to the indicator, surrounded by a coil.In both cases, the indicator is driven by magnetic torque caused by current flow in the coil.


What is a chair test for instruments?

Aricjcjvv


What are the Lab Instruments?

Test tube


What does Davis instruments offer in term on instruments?

Davis Instruments is a company that offers several technical weather instruments. These kinds of instruments are used to test the weather and atmosphere.


What happens to iron placed in a test tube with a stopper?

Iron and oxygen in a test tube alone will not react (observed by placing a piece of iron in a test tube with a stopper).Iron and water in a test tube alone will not react (observed by completely submerging a piece of iron in water in a test tube with a stopper).Iron, water and oxygen in a test tube will react (observed by placing a piece of iron in a test tube and submerging half of it with water). The following reaction will take place: iron + water + oxygen ----> hydrated iron(III) oxide. Hydrated iron(III) oxide is the chemical name for rust, which will appear as orange flaking on the piece of iron. To speed up this reaction you can use a bit of salt as a catalyst.


What is the result with iron II chloride in the test flame?

Iron has a yellow-gold color in the flame test.


What are the test instruments used in electronics?

Some test instruments used in electronics are:Multimeter - Used to measure voltage, ampere and resistanceOscilloscope - Used to measure frequency and oscillations


What is Tektronix test equipment good for?

Tektronix equipment is used for testing instruments and equipment. They test many different types of both equipmentss and instruments. The one you would need to test would depend on the instrument or equipment.


How can you test iron parts in water by filteration mathod?

how can i test iron parts in water by filteration method using sequestering agent


Why iron does not give flame test?

Iron DOES react to a flame test. According to the "handbook for prospectors and operators of small mines" the effect of oxy-gas flame on iron is: "ignites.sparkles;dark oxides". Are you certain that you are performing the test correctly ?


What has more kinetic energy shouting or whispering?

Kinetis energy is moving. So I don't think it uses any kinetic energy. Although, if this was in a test, i would guess shouting.


Give reason use of ammonia in limit test of iron?

Ammonia is limit test of iron because it is a chemical. Ammonia is a very story chemical.