Best Answer

The armature bushings inside the starter motor are probably shot. Time to replace the starter.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why does a cranking motor have an unusually high amperage draw accompanied by a slow cranking speed?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

A cranking motor has an unusually high amperage draw accompanied byslow cranking speed?

most likely a failing starter


Can you run a motor of greater amperage draw with a motor of less amperage draw?

It looks like you are asking if a higher amperage motor can replace a lower amperage motor. It depends on what the amperage difference is. If the amperage is high enough to move the capacity of the wire out of its rated value then it should not be done.Remember motor conductors have to be rated at 125% of the motors nameplate amperage. As the amperage increases so does the HP and the motor's protection will also have to be increased or the motor will trip the lower overload protection settings.Also keep in mind that if the motor is three phase, running a motor with higher HP on a load that does not need the extra HP, it will lower the power factor of the supply distribution.


What size breaker is needed for a 125 hp motor?

It depends on what the amperage of the motor is. The motors amperage depends on the voltage of the motor. The higher the voltage the motor operates on the lower the amperage. So unless the amperage from the motor's nameplate is stated an answer can not be given.Just remember that the feeder capacity to the motor has to be 125% of the motors full load amperage and the breaker protecting the conductors to the motor has to be rated at 250% of the motors FLA. This higher breaker size allows the motor to start without tripping a normal size breaker that is rated for the lower conductor size.


How cranking motor of automobile works?

tell me


What does LRA mean in electrical terms?

Locked rotor amperage is the amperage the motor draws when the voltage is first applied to the motor and the rotor has not started to turn. This amperage is usually up to 300% of the motors running amperage. Once the rotor starts to turn the motor generates a back EMF (electro motive force) that opposes the high inrush current. This back EMF drives the amperage down until the motor gets up to its rated speed at which time the motor amperage will be at its run amperage.


How much amperage is drawn by a kiloWatt motor?

To answer this question the motor voltage is needed.


If my AC technician says my unit is rated at 28.9 amps and drawing 24.8 and should draw about half of rated capacity and that compressor needs to be replaced Is this correct?

There are several amperage ratings on AC compressors/motors. Locked Motor Amperage (LRA) is the amperage that the motor is fused for. The load of the motor is expressed in amperage or wattage, which is probably the case here. Low amperage readings on an AC unit being charged by amperage load would indicate low freon. High amperage readings indicate overcharge when charging by the amperage load. AC units are not accurately charged by amperage readings and the efficiency of motors is not expressed in amperage readings.


When cranking the motor why does the hot wire on the coil go out?

When cranking, the ballast resistor is bypassed to give a hotter spark. If during cranking you do not have power at the coil, but when the key is turned to run you do; there is a problem with the bypass circuit (sometimes it comes from the starter motor solenoid wire)


Can a voltmeter be used to measure voltage in and out of a starter motor?

Voltage flow into a starter motor, never out of it. Use the voltmeter to measure the voltage at the starter motor before starting to crank and then whilst it is cranking. (Before cranking, the voltage appears across the starter motor relay only.)


What will happen to a motor if it is supplied with lower voltage than its rated voltage?

The amperage to the motor will go higher.


How many kw generator required for 7.5 hp motor?

To answer this question the motor voltage and amperage is needed.


How do you know if the starting motor is failing?

Good battery,slow cranking speed ,noisy,