Hi: Good question with many possible answers and one likely one. The valve is corroded at its seat face and leaking. Most likely needing replacement or re-machined seat face and matching seal. Hot water tends to do this a good bit. Be careful : let the thing completely cool and depressurise before you touch it. Never guess, heat energy stored in water is massive and will scald you faster than that 500 lb fish through your best hook. jimiwane >>>>>>>>>>>> Perhaps a problem with the expansion tank such as a bad bladder or an air leak if it`s not a bladder type of tank.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why does my boiler keeps losing water from pressure relieve valve?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Hot water baseboard heating system?

Hot water heating systems must be free of air to operate properly. The art of purging air from one of these systems comes with experience. There are usually purge setups in the piping, if the system was installed properly. The purge setup will consist of one ball valve or gate valve and one boiler drain somewhere in the loop or zone. There should be a half inch copper line connected to the water in the house that's used to fill the boiler and to purge air. This line will have an auto feeder valve somewhere between the tie into the water lines and the boiler. There is a lever on top of the auto feed valve. This lever is to override the automatic setting that keeps the boiler at the right pressure. When lifted up the lever allows city water pressure to be fed into the boiler. When the lever is down the setting will be somewhere between 12 and 25 pounds. This safeguards the system in case of a leak somewhere. Water will be added automatically. The way we purge the system is by hooking a hose to the boiler drain in the purge setup. Close the ball or gate valve and feed water through the system and out the boiler drain. The ball valve is to make sure the water we're putting in goes through the entire system before exiting. After the hose is hooked up and opened and the ball valve is closed, lift the lever on the automatic feeder and force city water into the boiler, around the loop your purging and out the hose. Be sure to watch the pressure gauge on the boiler and never exceed twenty five pounds. You will set off the pressure relief valve at 30 pounds. This is why the hose must be opened before the lever is lifted on the auto feeder. Put the hose end into a five gallon bucket and watch for air bubbles. Once the air bubbles have subsided, allow the system to purge for a few more minutes. Close the lever on the auto feeder and then the boiler drain. Open the ball valve and you're done.


Why do you need backpressure in your engine?

Back pressure regulates the release of exhaust into a slower stream that keeps the exhaust valve temperature more consistent.


How powerful is a pressure seal on a mason jar?

THe seal on a mason jar is totally airtight. This seal keeps foods preserved inside the jars.


The water in a drinking straw does not drip out when you press te top of the straw with your thumb or finger tip?

It's a matter of air pressure that acts on the water. When the straw is uncovered, there are two forces acting on the water inside. There is gravity, pulling the water down, and air pressure. The pressure is about the same on both ends of the straw, but on the top of the straw, the pressure pushes the water downward, and on the bottom of the straw, the pressure pushes upward. Both of the pressures are the same, so the net force is just the force of gravity pulling the water down and out of the straw. When you cover the top of the straw, you block the air from pushing down on the water. In this case, the only forces on the water are the air pressure pushing up, and gravity pulling down. However, the air pressure is a greater force than gravity, and keeps the water in the straw despite gravity's pull.


What is difference between gears and belts?

A belt is on the outisde and keeps everything together, where as a gear is on the inside and keeps moving.

Related questions

What keeps a crab from losing water?

Coelom


What are the most common boiler problems?

The most common boiler problems often arise because the boiler is not maintained. One is that in hard water areas the element is furred up and so it is not able to heat up the water as it should. Another is that the insulation is shifted and so no longer covers the boiler and keeps the heat in.


What pressure keeps lungs inflated?

Intrathoracic pressure


How do you know if your power steering has a leak?

If the reservoir keeps losing fluid.


The alternator and battery were placed on a Mazda 95' but the battery keeps losing charge and the car won't start The voltage is over 14 but the battery keeps losing power What causes this?

It could be the voltage regulator.


What keeps the inner core in a solid state?

high pressure


HSV 1 vs HSV 11?

The lusitaina had 3407 eggs in the boiler room, but napolean keeps his army's in his sleeves


If you have a high hairline does it mean your losing your hair?

Only if it keeps getting higher.


Why is there an overpopulation of cats in livonia?

Because Mrs. Kowalski keeps losing her cats!


what keeps The leaf from losing too much water from evaporation?

pls tell me


What to do if your furnace keeps blowing water out of the relief valve?

Nothing as a furnace is scorhed air a BOILER is either water or steam and "Relief Valves" are for liquid thus either you have a boiler or your furnace is being flooded from an outside source


How is Twitter going to survive if it keeps losing money?

It will eventually start to use advertising.