"Since the EMF generated by thermocouple circuits is a function of the difference in temperatures between the measuring junction and the reference junction, it is important that the reference junction be maintained at a constant, known temperature. This can be accomplished by (1) a temperature controlled oven, (2) an ice bath, or (3) an electrical means of simulating a known temperature."

Reference Quote from National Plastic Heater (http://www.nphheaters.com/technical/thermo_letter.htm)

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why is a reference temperature necessary when using thermocouples?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do they measure temperature?

Using different types of thermometers, thermocouples, thermal resistances, pyrometers, etc.


What is a sentence using the element name iridium?

Thermocouples that include an alloy of platinum and iridium are often used to measure temperature in a laboratory.


Can the temperature sensor be accurately calibrated without using a reference thermometer?

Put it into a temperature controlled enviroment


How do you convert output voltage of thermocouple into temperature?

You need to know the temperature of the reference junction and the voltage difference between the reference and sensing junctions. First, you convert the reference temperature to a voltage using the reverse equation or table for your thermocouple type. Then you sum that voltage with the measured voltage. Finally, you convert the summed voltage back to a temperature using the equation or table for the thermocouple type you are using. If the reference junction is at zero degrees C, you can skip the reference summing part. Before computer processing was easy and cheap, the reference junction was often kept in an ice water bath for that reason.


Is resistivity of a conductor temperature dependent?

A perfect insulator has infinite ohms of resistance.


It is not necessary to include a citation or reference when using a known fact such as the size of Greenland?

False. The size of Greenland is common knowledge and can easily be found, therefore, no citation or reference is needed. The answer would be true, the question says "It is NOT necessary" and it is not so the answer would be true.


How do you calibrate calibrators?

The thermocouple validation procedure is widely used for all furnaces and also in heating equipment. Thermocouples are non-adjustable measuring devices, so we cannot calibrate them. However, we can validate functioning for a range of temperature through using a thermocouple calibration bath.


Why was it necessary to let the ice sit out at room temperature for several minutes before using it in the experiment?

to guarantee the ice is at 0°C


What is an example of heat energy to electrical energy?

Devices called thermocouples do this directly. Boiling water and using the steam to turn turbines which turn generators do this indirectly.


Why have the letters in my Excel columns been replaced by numbers?

You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.You are using the R1C1 reference style. You can turn it off in the General tab in Options.


Is it necessary to pull out when using Nuva Ring?

no its not necessary.


How do you reference a maintenance code in IMDS?

By using the "Reference" hyperlink in the left navigation bar