A contactor not being energized or closed can be caused by a host of reasons . A shorted or open contactor coil. No control voltage or incorrect voltage present to energize the contactor coil , A safety device opening or breaking the control circuit . A loose or broken control devise or control wire . and possibly more , depending on your a/c units control wiring configuration. Tom H, HVAC proffesional. New Orleans .
conclusion
In a AC contactor, a shaded ring is essential to prevent it from buzzing twice a cycle. Ac contactor takes a input of alternating voltage resulting an alternating current and flux through its windings. So The contactor buzzes each time the magnitude of alternating magnetic field reaches zero. The shaded rings are provided at some part of the core. When the alternating flux cuts them the produce another alternating magnetic field which is out of phase from the main magnetic field. So the resultant magnetic field no more zero at the contacts and which prevents the contact from buzzing.
The conclusion of and air compressor is a supply of air. The air compressor generates air that is stored in a tank.
Checking the pressure of a fridge compressor is easy. Remove the compressor and give it a shake. After taking the compressor off it should make a sound while shaking that means itÕs still good if the compressor makes no sound that means it has went bad.
It is simply a piston compressor.
Not always. But if a compressor goes bad it can take out the contactor. I have replaced compressors before and found the contactor is still ok. In a commercial application Copeland will not honor the warranty if the contactor is not replaced at the same time a new compressor is installed. Not sure about residential but for a $15 contactor I would not gamble with it.
Ask your teacher. This is a no brainer...
Stuck compressor contactor.
a contactor is generally looks like a small box connected to an electric circuit. it is what controls electricity flow to a motor. in the middle is normally a way to push in the contactor to manually check to see if either the motor works or if you have electricity.
A defrost control typically.
Yes. Can blow capacitor, contactor or ground compressor.
compressor contactor is bad. probably stuck in the closed position.
Your contactor in the outdoor unit is stuck closed.
The relay actuated by the thermostat which starts and stops the compressor and condenser fan in the outdoor unit.
The contactor on the outdoor unit is probably stuck. Disconnect the power to the indoor unit, then disconnect the power to the outdoor unit and take a look at the contactor.
It could be you have a stuck fan relay, a contactor that is sticking, or your thermostat is bad.
Poor Airflow due to a dirty filter,dirty evaporator,dirty blower wheel, bad or weak run capacitor, or even a bad bearing in the fan motor causing it to overheat and shut off on overload while the compressor still runs, thus causing the unit to freeze up. On some systems it is possible that when the thermostat is satisfied and the indoor blower motor shuts off, the compressor could keep running if the contactor is sticking for 1 reason or another. Examples of this would be fireants or ladybugs in contactor or just an old contactor that has burnt points that stick some or all the time after running and getting hot. -Brad75-