A water pipe.
water pipe
Stenciling is used to identify the direction of flow and what the piping is used for such as fire supression ,gas , potable water ,etc
1. Replace the pipe, 2. Shut off the water
no
Supply coming from water source is a water service line.
A pipe,an fire extinguisher,rubber hose
It is a pipe standing out of the ground for firetrucks to get water from. Also known as a hydrant.
Fire stand pipe or domestic water?
ABOVE the sewer line and on an angle away
this is a 40 to 50 cm long flexible curved pipe made up of brass or copper or lead inserted in between the ferrule and the service pipe. this goose neck is provided to accommodate the possible movement, displacement or settlement that may take place between the water main and the service pipe due to water pressure and prevent damage to the connection.
The water from the house pipe rushes out with great speed in forward direction (action of house pipe on water).Then due to Newton's 3rd law of motion the house pipe moves in backward direction as a reaction.
For a 200amp service you need number 4 copper
Water main coming into house usually 3/4" K copper pipe. Depending on local plumbing code, fitting usually is flared or soldered.
That depends alot on your location and what codes your jurisdiction has adopted. From the 2006 International Plumbing Code, "water service pipe and the building sewer SHALL be separated by 5 feet of undisturbed or compacted earth." There are exceptions, 1. "the required separation distance shall not apply where the bottom of the water service pipe within 5 feet of the sewer is a minimum of 12 inches above the top of the highest point of the sewer and the pipe materials conform to Table 702.3. 2. water service pipe is permitted to be located in the same trench with a building sewer, provided such a sewer is constructed of materials listed in Table 702.3. 3. the required separation distance shall not apply where a water service pipe crosses a sewer pipe, provided the water service pipe is sleeved to at least 5 feet horizontally from the sewer pipe center-line on both sides of such crossing with pipe materials listed in Table 605.3, 702.2, or 702.3." So, no, there is no minimum separation IF the materials you are using bear the correct ASTM #. (Your building sewer pipe will probably have ASTM F 891 stamped on it.)
Hot? Cold? return? fire suppression ? Non Potable?
The problem sounds like the water pipe is not bonded to the ground wire of the distribution. These two wires should have a potential of zero between them once they are bonded together as per electrical code recommendations.This must be an older installation as nowadays most new water pipe installations use PVC to service a water supply to the home. In this case the PVC water supply pipe does not need to be bonded to the ground wire of the distribution service.