Can you hook up 208 volts on a 230 volt motor?

Yes, a 230 volt electric motor can run on 208 volts. The horsepower will be lowered by .9 or to 90% of the nameplate rating. e.g. A 230 volt 10 HP motor will only produce 9 HP at 208 volts. Note: If motor sees a load equal to its' rated HP it will over amp and shorten the live of the motor and/or trip out on internal overload.


Can I run a 230 volt 20 amp table saw on 10 3 with a 250 foot run?

Yes you can. If you don't need 120 volts at the saw then you can use 2Conductor # 10 copper wire. FYI, don't know if you know it, but you don't count the bare ground wire in the conductor count. Anyways With # 10 wire you will get a 6 volt drop at the end of 250 feet which is 2.5% leaving you a working voltage of 234 volts.


Will 220 volt work in a high volt 3 phase motor?

Yes a 208 voltage motor will operate on 220 volts. You have to increase the motor overload protection by 10% of the motor's full load amperage to protect the motor.


You want to wire up a receptacle to run a 2 hp 230 volt dust collector you have some NMD 90 14-2 available The run is about 50 feet from the panel Is this wire suitable and adequate?

No, NMD 90 14-2 wire is not suitable for a 2 hp 230 volt dust collector. You would need to use a wire with a higher ampacity such as NMD 90 10-3 wire to handle the current required for a 2 hp motor. Ensure to consult with a qualified electrician for proper wire sizing and installation.


Can you use a 230 Volt 1 phase motor with 208 volt 1 phase?

230 V is the standard nominal voltage in the UK. 'Nominal' means the 'stated' voltage, but this is allowed to vary, under government legislation, between +10% and -6%, which means it is allowed to drop to 216 V.The motor's rated voltage of 208 V is also a nominal voltage, but is not a standard UK nominal voltage so, without knowing what in which country the motor is manufactured, we'll assume that it is allowed to vary between, say, +5% to -5%. This means that it can operate at voltages up to 218 V. If it's allowed to vary between, say, +10% and -10%, then it can be operated up to 229 V.So there is an overlap between the nominal voltage of the supply and the rated nominal voltage of the motor so, in all likelihood, the motor should be able to run with a 230-V supply. On the other hand, there will be times when the supply voltage will exceed the upper limit of the motor's nominal voltage, and this may -over time- lead to a breakdown in its insulation and its ultimate failure.


How many amperes is a 150HP motor?

a 3 phase 415 volts 50 HZ 15 HP motor draws: 1. On no load 3.6 amp after a starting kick of around 18AMP 2. On a full load : a starting kick of 108 amp for few seconds and then18.3 amp. 3. On rated load(this means the motor is selected such that the load is 80% of the motor capacity) 14.64 amp with a starting kick of 88Amp.


How do you convert 12 volt 10 amps dc relay to 230 volt ac relay?

Unless otherwise specified, all a.c. voltages and currents are expressed in root-mean-square (rms) values. An rms value is exactly equivalent to a corresponding d.c. value. So, 230 V a.c. is exactly equivalent to 230 V d.c., and 10 A a.c. is exactly equivalent to 10 A d.c.Incidentally, the symbol for volt is 'V' (not 'v') and the symbol for ampere is 'A' (not 'a').


What size breaker for a 208 volt single phase motor that pulls 1.4 amps?

208 volts is not a common single phase voltage but you could just size your breaker to the capabilities of the conductor. 208 is normally a phase to phase voltage <<>> Many 230 volt motors can be connected to lower voltage supplies. These motors can be connected to supplies of 208 and 200 volts. The code requirement is that the 230 volt full load amperage of the motor be increased by 10% and 15% respectively for wire sizing and breaker selection. To answer the question you will need a two pole 15 amp breaker.


Can you run a 120 volt 5 amp window ac unit off a 12 volt deep cell battery with a 12 volt dc to 120 volt ac power inverter installed on the deep cell battery?

You "could" run a 120V 5A window AC unit off a 12V deep cell battery but, assuming 100% efficiency (something you can never get), you would need an inverter or motor-generator set and 50A out of the battery to run, and maybe 5 or 10 times that to start.


How do you run a 460 volt 60Hz motor with 460 volt 50Hz power?

If 50 hz is applied instead of 60 Hz, the speed of the motor will reduce by 10 hz equivalent. If you still want to keep the output speed equivalent to 60 Hz, you will have to use suitable gear box or so, to increase the speed to 60 hz equivalent.


Will a 10 hp 220 volt motor draw large amounts of electricity?

A single phase 10 HP motor will draw aproximately 50 amps. A three phase 10 HP motor will draw aproximately 28 amps.