end of the evaporator on the suction line

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

What are 3 operating pressures of a txv in a air conditioned unit?

In an air conditioning unit, a thermal expansion valve (TXV) operates under three primary pressures: the high-side pressure, which is the refrigerant pressure after it leaves the condenser; the low-side pressure, which is the refrigerant pressure before it enters the evaporator; and the bulb pressure, which is created by the refrigerant in the sensing bulb attached to the TXV. The TXV modulates the flow of refrigerant into the evaporator based on the bulb pressure, ensuring optimal cooling efficiency by maintaining the correct superheat level.


Equalizing lines should be located in multiple condenser and compressor applications where Between condenser and evaporator coils or Near the TXV or Between compressors and condensers or None of them?

oppisite side of txv sensing bulb on outlet of evaporator (suction line)


What is the different between exv and txv?

Difference between txv and exv.


How can you install an txv?

To install a thermal expansion valve (TXV), first, ensure the system is off and properly evacuated. Remove the old valve and clean the mounting surfaces before installing the new TXV, ensuring it aligns with the refrigerant lines. Secure it in place with the appropriate hardware and connect the sensing bulb to the suction line as specified by the manufacturer. Finally, check for leaks, recharge the system, and test the operation.


Effect of moisture on thermostatic expansion valve?

None, a TXV operates by it's sensing bulb sensing superheat of the suction line as it exits the evaporator coil.


What is the purpose of the external equalizer on a TXV?

The purpose of the External equalizer on the TXV is to compensate for the pressure drop in the evaporator coil , This is done since the superheat calculation is based on the difference in the Saturation temperature corresponding to the Suction pressure (Measured after the coil) and the actual suction line temperature. Now, in a TXV measurement of actual line temperature is accomplished by using the Sensing Bulb and the Measurement of the Suction pressure by the External Equalizer of the TXV. The opening/Closing of the Expansion valve is controlled by the setting of the superheat which is governed by the setting of the Spring.


Will the Evaporator Pressor Regulating valve close if the Thermostatic Expansion Valve is in the evaporator air stream?

The EPR valve should work reguardless of if the TXV is in the air stream. The TXV in the airflow shouldn't make it act any different since it is sensing the temperature at the bulb instead of at the valve it's self.


Don't burn bulb base up?

Unavoidable in certain situations. Light fixtures are sometimes mounted in the ceiling - the bulb must then be mounted base up or base horizontal.


Which is not a pressure or force actingon a TXV diaphragn?

Temperature is not a pressure or force acting on a TXV diaphragm. The pressure and forces that typically act on a TXV diaphragm are the evaporator pressure, spring force, and spring adjustment. Temperature indirectly influences the operation of the TXV by affecting the refrigerant pressure.


Is it ok to undersize a txv?

No, it is not.


Chevy Avalanche high mounted tail light out?

change the bulb


Which is not a pressure or force on a txv diaphragm?

Temperature is not a pressure or force acting on a TXV (Thermostatic Expansion Valve) diaphragm. The TXV diaphragm is primarily influenced by refrigerant pressure and spring force to regulate the flow of refrigerant into the evaporator coil. Temperature affects the superheat setting of a TXV but is not a direct force acting on the diaphragm.