what two places heat be deposited in a water cooled condenser
A water jacketed condenser in distillation works by cooling the vaporized substance from the distillation process using water flowing through a jacket surrounding the condenser. This cooling causes the vapor to condense back into a liquid form, which can then be collected as the distillate.
Because the water flowing into the condenser will be warmer on exiting the system. While it doesn't make a huge difference, having colder water at the end of the condenser means that gases with lower volatility will have a greater chance of condensing before passing out of the system :)
Water enters the condenser at the lowest point to ensure efficient cooling by maximizing contact between water and hot refrigerant vapors. Having water exit at the highest point allows for air trapped in the system to be released easily, preventing air pockets that could hinder heat transfer efficiency. This setup also helps prevent water hammering by allowing air to escape as water flows out.
If the water flow in a Liebig condenser is reversed from its intended direction, the cooling efficiency will decrease and the condensation of vapor inside the condenser will be less effective. This can result in lower overall condensation efficiency and potentially affect the distillation process taking place.
The inside of the air conditioner condenser can be cleaned by removing the hoses and running water through the condenser. Run water through the condenser until the water exiting the condenser is clear.
The temperature of the water leaving the condenser would depend on the amount of heat removed from the water in the condenser. Without this information, it is not possible to accurately determine the temperature of the water leaving the condenser.
Water vapor condenses in a cold condenser tube.
In distillation, water evaporates from the condenser due to a difference in temperature between the hot vapor coming from the boiling flask and the cold surface of the condenser. This temperature difference causes the water vapor to condense into liquid form on the condenser surface, resulting in the separation and collection of the distilled water.
The approach temperature difference (ATD) is used to determine the condenser performance of a water-cooled condenser. It is the temperature difference between the refrigerant condensing temperature and the cooling water inlet temperature. A lower ATD indicates better performance and efficiency of the condenser.
When a system with a water-cooled condenser cycles off, the water regulating valve should
When a system with a water-cooled condenser cycles off, the water regulating valve should
The water instantly cools one condenced.
so as to cool the vapor as the water stays little time till the condenser is filled with water
The heat absorbed by the condenser medium in a water-cooled condenser can be deposited either into the environment through the cooling water, which carries the heat away from the system via a cooling tower, or into another part of the system to be reused for heating purposes, like in a heat exchanger for a district heating system.
this question makes -3 sense
condenser approach is heat transfer the water to gas of condenser efficiency is good less then below (2 F) the system is working good.