answersLogoWhite

0

What else can I help you with?

Continue Learning about Civil Engineering

Briefly explain the difference between the end bearing piles and the friction piles?

4. End-bearing piles. Typical end-bearing piles aredriven through very soft soil, such as a loose silt-bearingstratum underlain by compressible strata. Rememberthis factor when determining the load the piles cansupport safely.5. Friction piles. When a pile is driven into soil offairly uniform consistency and the tip is not seated in ahard layer, the load-carrying capacity of the pile isdeveloped by skin friction. The load is transferred to theadjoining soil by friction between the pile and thesurrounding soil. The load is transferred downward andlaterally to the soil


What type of foundation is used for load bearing strctures?

Load-bearing structures typically use deep foundations, such as pile foundations or drilled shafts, to transfer loads to stable soil or bedrock. Shallow foundations, like spread footings or mat foundations, are also common for smaller structures where the load can be supported by the soil near the surface. The choice between deep and shallow foundations depends on factors such as soil conditions, load requirements, and structural design.


What is the difference between pile and pillar?

pile is a type of footing,its necessary where the soil strength is low quality,AND piller is a vertical structure which carrying load from slab and pass to footing,its also known as COLUMN.


What is spun pile and micro pile?

Spun Pile is the pile that they produced at the factory and bring it to the worksite.It is almost the same with Bored Pile,but in side is hole.


What is a skirt pile?

A skirt pile can refer to a pile of clothing in a female's dressing room. Also, a skirt pile can be a pile of dirt or rocks that are pushed to the side when clearing with large equipment.

Related Questions

What is ultimate load test to bored pile?

The question itself is not correct.It should be what is the ultimate load carrying capacity of bored pile?Ans: Ultimate load carrying capacity of pile could be determined be conducting load test.Ultimate load:The load at which the pile continuously settle.orthe load at which settlement of the pile reaches 10 percent of its diameter


What is the allowable eccentricity of pile?

Pile eccentricity will allowable up to maximum 75mm. Above that we can proceed pile cap works by increasing the size of pile cap.


How can check the capacity of pile foundation?

This can be done by physically loading the pile by a test load which is 1.5 times the design load on the pile, or by other indirect methods like dynamic test methods. D mohan


What are the applications of pile load testing?

Pile load testing is primarily used to determine the load-bearing capacity of piles in foundation engineering. It helps ensure the structural integrity and safety of buildings and bridges by verifying that piles can support the expected loads. Additionally, it aids in the design process by providing empirical data for load distribution, settlement, and overall performance of the foundation system. Pile load testing is also critical for quality control during construction and can identify any potential defects or weaknesses in the piles.


What do pile load tests determine?

In simple words, It basically determines the load bearing capacity of rock below the earth surface. If soil is weal enough that it can not support the load, then we bore below earth and find out rock location and conduct pile load testing to measure load bearing capacity. For example, pile foundation are provided are provided in highway bridge foundations if soil is weak...... Geotechnical Engineering.......


What is allowable eccentricity for pile?

Concrete piles cannot be driven at precise intended location; This is true for bored piles also. For practical reasons various country design codes restrict the permissible deviation. In Indian code this value is specified as 75 mm. This plays important role in pile-cap design. The deviation smaller than this will never be reported. So pile cap sizing needs to be based on the worst possible direction deviation. The pile eccentricity is one of the important aspects in pile cap shear strength calculation as well as pile cap reinforcement calculation.


How do you measure eccentricity of pile?

The eccentricity of a pile is typically measured by determining the horizontal distance between the pile's centerline and the applied load or resistance. This measurement is crucial in structural design to ensure the pile can safely bear the intended loads without excessive deflection or failure. Eccentricity must be within specified limits to prevent structural issues or stability concerns in pile-supported structures.


Is a pier a pile foundation?

pile is the steel layer and pier is the outer most layer'


What is necking in piles?

Necking in piles refers to a phenomenon that occurs during pile installation or loading when a portion of the pile's shaft experiences localized deformation or reduction in cross-sectional area. This can result from excessive loading, improper installation techniques, or material defects. Necking can compromise the structural integrity and load-bearing capacity of the pile, potentially leading to failure or reduced performance. It is important to monitor and address necking to ensure the stability of foundations in construction projects.


What is the maximum Test Load on Pile have been carried out?

2.5 times of design load


What is the is code for pile load test?

IS 2911 part 4


Briefly explain the difference between the end bearing piles and the friction piles?

4. End-bearing piles. Typical end-bearing piles aredriven through very soft soil, such as a loose silt-bearingstratum underlain by compressible strata. Rememberthis factor when determining the load the piles cansupport safely.5. Friction piles. When a pile is driven into soil offairly uniform consistency and the tip is not seated in ahard layer, the load-carrying capacity of the pile isdeveloped by skin friction. The load is transferred to theadjoining soil by friction between the pile and thesurrounding soil. The load is transferred downward andlaterally to the soil