well first off, the electronics in the tv rely on the 50 hz signal to get the clock going right to show the picture, so you'll have to get some sort of power converter, then the tv will only accept PAL signals. So as far as watching broadcasts, it wont recognize NTSC which is used in the US. so if you have a PAL DVD player or something you can watch that, but anything you plug into the TV must be PAL.
There is no inherent disadvantage of 50 Hz compared with 60 Hz, bearing in mind that systems that run at 50 Hz are designed to run at 50 Hz.
10 Hz 10 Hz
60 Hz in North America, 50 Hz in Europe.
If the load is non inductive and straight resistive then there is no problem. Inductive loads like motors, a 60 Hz device can be used on 50 Hz but it is much harder on the equipment if 50 Hz is used on a 60 Hz system.
Answer 1000 RPM or 16.667 HZ, 50 Hz * 60 = 3000 RPM 3000 / 3 = 1000 RPM, or 50 HZ / 20 (1/3 of 50 Hz) * 60 seconds. Or Hz * 20 ( converts to RPM) For 4 pole then, Hz * 30 = RPM For 8 pole, Hz * 15 = RPM
Probably .. the fan will run a bit slower and the motor will get a bit hotter the timer will change from 1 hr to 1.16 hours
Europe uses 230V used to be 240 but was changed a few years back. In France, voltage is 220V and frequency is 50 hertz
Nothing happens. The stereo has a transformer that converts the power to DC, and 50 or 60 Hz input makes no difference.
There is no inherent disadvantage of 50 Hz compared with 60 Hz, bearing in mind that systems that run at 50 Hz are designed to run at 50 Hz.
Hi - it should be OK but the transformer might overheat a little if it is used intensively, so it need to be used carefully. The reason is that the magnetic flux in the core is 15-20% greater at 50 Hz, and that increases the heat produced in the transformer. Going in reverse, a 50 Hz transformer will work fine on 60 Hz.
There is nothing to convert. You are using the same unit of measurement. A hertz is a hertz, all you are dealing with is 10 less Hertz. 60 Hertz - 10 Hertz = 50 Hertz The difference is 10 Hertz. The math there is just to give you a clear example and illustrate my point. What you are asking for is similar to someone asking "how do you convert miles to miles" or "how do I convert inches to inches".
220VAnswer220 V @ 50 Hz, Plug is G.
10 Hz 10 Hz
The mains voltage in Cyprus is 230 volts at a frequency of 50 Hz.
If a bulb has 50 Hz frequency and it's supply is 60 Hz frequency, it will still glow, despite the allowance of 10 HZ frequency.
Not without spending a great deal of money. Appliances with motors and timers at 50 Hz would have to be changed out to 60 Hz components. Appliances that are strictly of a resistive nature will operate without any problem.
60Hz frequency on 50 Hz motor will create more resistance in its coils. Will cause electromagnetic force trying to increase the speed of the rotor by about 20 %. Less current will flow but the torque will be less, because of the increased resistance of the coils. Usually if the motor is not loaded much it will work fine on 60 Hz. One solution if there is problem running the motor is to remove part of the all coils equally from all of the bobbins by 10-20% .CommentThe resistance of the coils will remain unchanged, however, their inductive reactance will increase -thus reducing the current.