An open neutral means the neutral wire is disconnected or broken. You will have to remove the outlet and find out which is the case. The wire may also be broken.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Electrical Engineering

Why is it that when you touch the neutral in a box that is not connect to the panel cause the test light to come when touching the power wire?

It shouldn't. The open end of a non connected neutral should have the same potential as the voltage feeding the circuit. The only time a voltage will show is when the return neutral is tested with a meter to the neutral bar or the ground return bar. It will then show what the supply voltage to the connected load is. Once this neutral is connected to the neutral bar there will be no voltage shown across the test meter between the neutral and the neutral bar or the ground bar.


What is exactly the function of Neutral link in an electrical circuit?

To protect a circuit, we use a fuse or circuit breaker. The fuse or circuit breaker must always be placed in the lineconductor, never in the neutral conductor. So, if we want to completely isolate a circuit from the supply, we must remove the fuse from the line conductor, and open the link in the neutral conductor. A 'link' is a non-fusible metal break point in the neutral.


What is use of neutral link?

In a MEN (Multiple Earth Neutral) system, the neutral wire is connected to the earth wire at the switchboard. This is the neutral link. From an electrical point of view the neutral pin and the earth pin in a power socket are at the same potential but from a safety point of view they are different. A residual current device (RCD) (or earth leakage core-balance-relay(ELCBR)) sits in series with both the active and the neutral feed and a leakage from either wire to ground (via a human or water leak in a washing machine etc) will trip the circuit breaker that is in the RCD.Another AnswerFuses or circuit breakers must be inserted into the line conductor, never into the neutral conductor. However, if we need to isolate the circuit, we must place a break in both the line and the neutral conductors. We can achieve this for the line conductor by, for example, removing the fuse. To achieve the same with the neutral conductor, we can open the neutral link, which is simply a short length of conductor inserted between a pair of terminals in the neutral.


Why is the outlet 86 volts instead of 120 in your outlet?

There may be an "open neutral" somewhere either in your breaker panel or in the meter base. Contact a qualified electrician to help solve the problem. An open neutral causes one leg of the electrical service to be "low" voltage, while the other leg goes "high". That can result in premature failure of electrical components, such as light bulbs, electronic devices and electric motors.


Where is the likely point to start fire due to loose neutral wire?

The most likely place for heat build up in an electrical system, and hence fire, is the point with the most resistance. In this case right exactly where the loose neutral is.However, for an electrician, the task of fixing a loose neutral is generally very small. It shouldn't take more than 10 minutes to locate and fix, and so, no more fire!If in doubt, please contact a registered electrician.

Related Questions

How can I fix an open neutral in my electrical system?

To fix an open neutral in your electrical system, you should first turn off the power to the affected circuit at the breaker box. Then, identify the neutral wire that is not properly connected or broken. Reconnect or replace the neutral wire as needed, ensuring it is securely attached. Finally, turn the power back on and test the circuit to ensure the issue has been resolved. If you are unsure or uncomfortable working with electrical systems, it is recommended to contact a licensed electrician for assistance.


How can I fix an open neutral outlet?

To fix an open neutral outlet, you should first turn off the power to the outlet at the circuit breaker. Then, check the wiring connections at the outlet to ensure they are secure. If the neutral wire is loose or disconnected, reattach it securely. Finally, turn the power back on and test the outlet to ensure it is working properly. If you are unsure or uncomfortable working with electrical outlets, it is best to contact a qualified electrician for assistance.


How can I fix an open neutral outlet in my home?

To fix an open neutral outlet in your home, you should first turn off the power to the outlet at the circuit breaker. Then, remove the outlet cover and check the wiring connections to ensure the neutral wire is securely connected. If the neutral wire is loose or disconnected, reattach it properly. Finally, test the outlet with a voltage tester to ensure it is working correctly before turning the power back on. If you are unsure or uncomfortable with electrical work, it is best to consult a professional electrician for assistance.


How do you fix a zipper that has split open?

You can fix a zipper that has split open by clamping it with a pliers


How do you fix auto transmission on eunos 30x?

how to fix auto transmission on eunos 30x . no reverse or neutral..


Where can I open on the machine to fix the belt problem?

I can open an belt side part to fix the belt


How can I determine how to find an open neutral in an electrical circuit?

To find an open neutral in an electrical circuit, you can use a multimeter to test for continuity between the neutral wire and the ground wire. If there is no continuity, it indicates an open neutral. Additionally, you can visually inspect the wiring for any signs of damage or loose connections.


What does an open neutral mean?

Typical home wiring will have one hot wire, one neutral wire, and one ground wire per circuit. An open neutral would indicate that the neutral wire, usually white wire, is broken.


When the neutral switch is open where do the line current flow to?

There is never a switch installed in a neutral line.


How can I use a multimeter to test for an open neutral in an electrical circuit?

To test for an open neutral in an electrical circuit using a multimeter, set the multimeter to measure AC voltage. Then, place the black probe on the neutral wire and the red probe on the hot wire. If the reading shows a voltage close to zero, the neutral is likely open.