Arcing is caused by current trying to sustain its flow by using the air as a conduit. If the travel is very far the arc will dissipate as lack of paths. If the current is great it may sustain itself. All contactor have a biult in shoot trough to channel the energy harmlessly, A capacitor across the contacts can help by absorbing the difference in voltage when the contacts disconnect or connects

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you prevent arcing in electrical contacts?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How can i clean contacts of an electrical breaker?

You shouldn't have to clean the contacts. If they aren't working, it's often due to damage from arcing. However, you can use compressed air, air in a can, or electrical contact cleaner, only after the main bus is de-energized and the breaker is removed from the panel. Contact cleaner is a liquid, and should not be sprayed into a live bus or breaker.


What are the two reasons for arcing at the commutator?

A shorted coil or shorted coils in the rotor will cause arcing at the commutator. It should also be noted that if the brushes are damaged badly enough where they make contact with the commutator, this can cause arcing. Oh, and let's not forget that a stuck brush or brush spring will prevent a brush from making proper contact with the commutator. Arcing can result from that, too.


Why are starter contacts silver plated?

Silver has the least tendency for arcing and damage from repeated engagements. Silver lasts a lot longer than copper. Gold is also used too but is more expensive.


Why does the electricity go out when it is storming?

Storm related electrical outages may occur for a variety of reasons, most of which are caused by lightning strikes, fallen trees, or weather related damage to the components of the electrical system. If a major storm produces severe flooding, the local electrical power may be turned off to prevent accidental electrocution and to prevent damage to the main electrical grid infrastructure.


Which IS a common sense safety procedure that can help prevent electrical accidents?

The main safety rule is to switch off at the mains before working on electrical equipment and wiring.

Related questions

Do electrical plugs cause sparks that start fires?

they can because bad contacts can cause arcing which can ignite combustible material near by.


What are arcing contacts?

Whenever an electrical contact is made or broken, an electrical spark jumps through the air between the two contact points while they are very close together but not yet, or not any longer, touching. That spark jumping is an electrical arc and the event is arcing contact. The main cause of arcing is the property of a circuit to maintain the continuity of the current, so whenever the contacts separate to break the circuit the air (or any dielectric medium that is used) ionises and continuity of the current is maintained, at least momentarily.


How can i clean contacts of an electrical breaker?

You shouldn't have to clean the contacts. If they aren't working, it's often due to damage from arcing. However, you can use compressed air, air in a can, or electrical contact cleaner, only after the main bus is de-energized and the breaker is removed from the panel. Contact cleaner is a liquid, and should not be sprayed into a live bus or breaker.


How was the light switch created?

The original light switch was invented in 1884 by John Holmes. This switch was made to prevent "arcing" of the electrical circuit, and the design is still in use today.


What is arcing in gas engine?

If I understand your question correctly, arcing is when an electrical charge jumps inside the distributor from the main electrical prong to the prongs that supply electric power to the spark plugs.Hope this helped,Evan


What is arching in electricity?

Arcing is electrical current jumping across a gap, or creating an arc, as in a spark plug firing, or lightning arcing across the sky.


Why does your Saturn SL2 dome light only work if you smack it multiple times?

It could be corroded bulb contacts, switch contacts or other electrical connection. Clean the contacts and coat them with electrical contact grease to prevent future corrosion. OR it could also be just a defective bulb. Same thing happens on light bulbs in my home AND headlights on my car.


What could be the cause of arcing between the buss bar and a breaker?

Arcing is caused by a poor electrical connection. The breaker is not making good contact with the buss bar. Try replacing the breaker.


What is arcing length in steel melting?

Please rephrase the question. Are you describing an electrical furnace or the welding process?


What are reasons for arcing at the commutator?

A shorted coil or shorted coils in the rotor will cause arcing at the commutator. It should also be noted that if the brushes are damaged badly enough where they make contact with the commutator, this can cause arcing. Oh, and let's not forget that a stuck brush or brush spring will prevent a brush from making proper contact with the commutator. Arcing can result from that, too.


What happens when NC and NO contacts not work in electrical panel?

When a NC and NO contacts are not working the NC will not open and the NO will not close.


What is restriking voltage?

Restriking voltage is transient voltage. During the arcing time, at current zero, the voltage that shows up across the contacts is the restriking voltage.