Nine tenths of the voltage would appear across the 200-ohm coil.
There are mainly two types of starting methods. Reduced voltage starting and across the line starting. Reduced voltage starting comes in the configuration of the wye-delta starter. Across the line starter is the combination of voltage source, motor contactor and motor load. The utility company's policy is set, to allow only a certain horsepower load to utilize across the line starting. This is in the neighbourhood of 25 HP up to 50 HP. High horsepower loads draw high current, up to 600%, of the motors full load rated amps. This high current inrush tends to draws the line voltage down and to prevent this condition wye-delta starters must be used. In the electrical market today solid state soft starts have taken the place of wye delta starters. When using a three phase contactor across the line for motor starting, a three phase overload block must be used. The wiring of the contactor consists of taking L1, L2 and L3 of the supply voltage and connecting it to the top of the contactor on terminals L1, L2 and L3 of the contactor. The motor load is connected to T1, T2 and T3 on the bottom of the overload block. If you are using a three wire control for operating the contactor, the contactor must have a N.O. contact on it to seal the contactor in once the contactor coil has been energized. The overload block has three N.C. contacts, one for each leg of L1, L2 and L3. These three contacts are wires in series to the stop - start circuit. Years ago on old schematic diagrams these contacts used to be placed on the down stream side of the magnetic starter's coil (between the coil and the neutral). When the overloads tripped the voltage was left on the control circuit which was found to be dangerous for trouble shooting. Now for safety reasons, the overload contacts are positioned in the beginning of the start- stop circuit so that when a overload trips, the whole stop - start circuit becomes de-energized.
Arcing is caused by current trying to sustain its flow by using the air as a conduit. If the travel is very far the arc will dissipate as lack of paths. If the current is great it may sustain itself. All contactor have a biult in shoot trough to channel the energy harmlessly, A capacitor across the contacts can help by absorbing the difference in voltage when the contacts disconnect or connects
What the heck is the vz6. Zeners can protect overvoltags from damaging circuits. Two reversed zeners control AC currents.
v of what? v across what? v measured from what 2 points? v across the coils? v across the resistor? v across the coils and resistor? v across the battery? v across the battery and coils? v across the battery and resistor? or are you asking what v stands for? v stands for voltage.
2
A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.
It is a type of starter that allows a motor to be started across the line by starting the motor with a reduced inrush current. The motor is started in a wye configuration until it gets up to speed and then a timer drops the wye contactor out a draws the delta configured contactor in. The motor then operates in a delta wired configuration.
That is the star point contactor that opens when it goes into the delta configuration.
Nine tenths of the voltage would appear across the 200-ohm coil.
There are mainly two types of starting methods. Reduced voltage starting and across the line starting. Reduced voltage starting comes in the configuration of the wye-delta starter. Across the line starter is the combination of voltage source, motor contactor and motor load. The utility company's policy is set, to allow only a certain horsepower load to utilize across the line starting. This is in the neighbourhood of 25 HP up to 50 HP. High horsepower loads draw high current, up to 600%, of the motors full load rated amps. This high current inrush tends to draws the line voltage down and to prevent this condition wye-delta starters must be used. In the electrical market today solid state soft starts have taken the place of wye delta starters. When using a three phase contactor across the line for motor starting, a three phase overload block must be used. The wiring of the contactor consists of taking L1, L2 and L3 of the supply voltage and connecting it to the top of the contactor on terminals L1, L2 and L3 of the contactor. The motor load is connected to T1, T2 and T3 on the bottom of the overload block. If you are using a three wire control for operating the contactor, the contactor must have a N.O. contact on it to seal the contactor in once the contactor coil has been energized. The overload block has three N.C. contacts, one for each leg of L1, L2 and L3. These three contacts are wires in series to the stop - start circuit. Years ago on old schematic diagrams these contacts used to be placed on the down stream side of the magnetic starter's coil (between the coil and the neutral). When the overloads tripped the voltage was left on the control circuit which was found to be dangerous for trouble shooting. Now for safety reasons, the overload contacts are positioned in the beginning of the start- stop circuit so that when a overload trips, the whole stop - start circuit becomes de-energized.