A Vector group is the International Electrotechnical Commission (IEC) method of categorizing the primary and secondary winding configurations of three-phase Transformers. Within a polyphase system power transformer it indicates the windings configurations and the difference in phase angle between them. The phase windings of a polyphase transformer can be connected together internally in different configurations, depending on what characteristics are needed from the transformer. For example, in a three-phase power system, it may be necessary to connect a three-wire system to a four-wire system, or vice versa. Because of this, transformers are manufactured with a variety of winding configurations to meet these requirements. Different combinations of winding connections will result in different phase angles between the voltages on the windings. This limits the types of transformers that can be connected between two systems, because mismatching phase angles can result in circulating current and other system disturbances. Symbol designation The vector group provides a simple way of indicating how the internal connections of a particular transformer are arranged. In the system adopted by the IEC, the vector group is indicated by a code consisting of two or three letters, followed by one or two digits. The letters indicate the winding configuration as follows: * D: Delta winding, also called a mesh winding. Each phase terminal connects to two windings, so the windings form a triangular configuration with the terminals on the points of the triangle. * Y: Wye winding, also called a star winding. Each phase terminal connects to one end of a winding, and the other end of each winding connects to the other two at a central point, so that the configuration resembles a capital letter Y. The central point may or may not be connected outside of the transformer. * Z: Zigzag winding, or interconnected star winding. Basically similar to a star winding, but the windings are arranged so that the three legs are "bent" when the phase diagram is drawn. Zigzag-wound transformers have special characteristics and are not commonly used where these characteristics are not needed. * III: Independent windings. The three windings are not interconnected inside the transformer at all, and must be connected externally. In the IEC vector group code, each letter stands for one set of windings. The HV winding is designated with a capital letter, followed by medium or low voltage windings designated with a lowercase letter. The digits following the letter codes indicate the difference in phase angle between the windings, with HV winding is taken as a reference. The number is in units of 30 degrees. For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding leads the HV by 30 degrees. The point of confusion is in how to use this notation in a step-up transformer. As the IEC60076-1 standard has stated, the notation is HV-LV in sequence. For example, a step-up transformer with a delta-connected primary, and star-connected secondary, is not written as 'dY11', but 'Yd11'. The 11 indicates the LV phase lags 30 degree behind the HV side. Transformers built to ANSI standards usually do not have the vector group shown on their nameplate and instead a vector diagram is given to show the relationship between the primary and other windings.

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

What is phase shift in three phase transformer?

The phase shift in three-phase transformer from winding of Transformer and determine by vectorgroup of transformer such as YNd1 High voltage connect to wye Low Voltage connect to delta so L.V. lag H.V 30 degree.Answer'Phase shift' or, more accurately, 'angular displacement', is the angle between the secondary line voltages and primary line voltages of a three-phase transformer.


Can you lower 277v to 240v?

Yes, you can lower the voltage from 277V to 240V using a transformer. A transformer can step down the voltage while maintaining the same frequency. Make sure to select the appropriate transformer with the correct voltage rating for the input and output you need.


What Device used to select amount of voltage in primary coil of step up transformer?

There is no selective device to determine the amount of voltage. A transformer is selected by the voltage available at the site for the primary and the load on the secondary side of the transformer.


How do you figure out maximum current of a 240V transformer circuit?

Your best bet is to go to Acme Transformer on the web and once you are on their web page select how do I rate a transformer, they have everything single phase 3 phase step up step down.


What is the best way to select and install a 300 watt low voltage transformer for outdoor lighting?

To select and install a 300 watt low voltage transformer for outdoor lighting, first calculate the total wattage of your lighting fixtures to ensure it does not exceed the transformer's capacity. Choose a transformer with a wattage rating higher than your total wattage needs. Install the transformer in a dry, well-ventilated area close to a power source, following the manufacturer's instructions for wiring and mounting. Regularly check for proper functioning and safety.


What is the best way to select and install a 12v LED transformer for optimal performance and efficiency?

To select and install a 12V LED transformer for optimal performance and efficiency, consider the following steps: Determine the total wattage of the LED lights you plan to connect to the transformer. Choose a transformer with a wattage rating that is higher than the total wattage of the LED lights to avoid overloading. Ensure the transformer is compatible with 12V LED lights and has the appropriate voltage output. Install the transformer in a well-ventilated area to prevent overheating. Connect the LED lights to the transformer following the manufacturer's instructions. Test the setup to ensure proper functionality and adjust as needed for optimal performance and efficiency.


What type of transformer configuration will you select to design a high input impedance and low output impedance amplifier?

main volage


How do you convert 120vac to 24vac?

You can use a step-down transformer to convert 120VAC to 24VAC. Select a transformer with a ratio of 5:1, which will step down the voltage appropriately. Be sure to follow proper safety precautions when working with electricity.


How can I convert 110v to 12v using a transformer?

To convert 110v to 12v using a transformer, you would need a transformer with a turns ratio of 9.17:1. This means the primary winding (110v) would have 9.17 times more turns than the secondary winding (12v), allowing for the voltage conversion. Make sure to select a transformer with the appropriate power rating to handle the load at 12v.


Calculating appropriate low voltage transformer for outside low voltage lighting?

calculate the total sum of lighting power and add 10% as safe operation of the transformer. then select a transformer for that rating. suppose your total lighting power is 300VA. add 10% of the total lighting power so the total power is 330VA. therefore your transformer size can be 330va or more. please follow IEE regulations.


HOW do I SELECT A STEP DOWN TRANSFORMER?

By looking to the number of turns in the Primary and Secondary Coils. "A Step down transformers are designed to reduce electrical voltage. Their primary voltage is greater than their secondary voltage. This kind of transformer "steps down" the voltage applied to it."


What is a half transformer and a half transformer?

a hole transformer