answersLogoWhite

0

If the frequency is kept the same, you will overexcite the transformer, and it will draw excessive current (similar to inrush currents). Insulation tests are performed on Transformers above nominal voltage, but they are performed at higher than rated frequency to keep the volts per hertz roughly equal to prevent overexciting the core.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Electrical Engineering

Can a 2-pole circuit breaker be used for 110V 220V or 440V?

All three, on 110V a split receptacle, on 220V a baseboard heater, on 440V a construction heater or similar resistive load.


What happen to the 480v rated motoe when connected to 440v power?

Depending on the design of the motor, it may just run with less torque/hp. It might run slightly hotter as well, depending on the load.


Can you get 120v single phase from 440 3 phase?

Yes, you can obtain 120V single-phase power from a 440V three-phase system using a transformer. By using a step-down transformer that reduces the voltage from 440V to 120V, you can safely access single-phase power. It's important to ensure that the transformer is correctly rated for the load and that all safety regulations are followed during installation. Always consult with a qualified electrician for any electrical work.


Why do you use single phase in house wiring?

bcoz we dont require too much voltage when working in home so in home generally 220v is preferred & in industries 3phase connection is used for heavy loads (440v)


When two bulbes with 25W and 100W rated at 220V are connected in series with a supply of 440V which will fuse?

The 25w bulb, since it has the much higher resistance. The resistance can be derived from:P = V^2/RR = V^2/PFor the 100w bulb:R = 220^2/100 = 484 ohmsFor the 25w bulb:R = 220^2/25 = 1936 ohmsWhen connected in series, and then connected to 440V, the voltage across the 100w bulb would be:V = 440*484/(484+1936) = 88VThis is well within spec.The voltage across the 25w bulb would be:V = 440*1936/(484+1936) = 352vThis is way over spec, and would cause the bulb to fuse.Although this answer assumes that a light bulb is a linear resistor, they are not. The resistance of a light bulb changes significantly with voltage and filiament temperature. The 25w light bulb is still the one that fuses, but the non-linearity of the resistance needs to be understood.

Related Questions

How can 440V equipment operate on 220V?

440V equipment cannot operate directly on 220V. You would need a step-up transformer to increase the voltage from 220V to 440V for the equipment to function properly. Attempting to power 440V equipment with 220V without the proper transformer can damage the equipment and pose a safety risk.


What is the formula to convert amperes from 440V to 460V?

For the same power - Watts - you need to run twice as many amps at 220V than at 440V. For the same load, it'll pull half the amps at 220V than it did on 440V


Can a 2-pole circuit breaker be used for 110V 220V or 440V?

All three, on 110V a split receptacle, on 220V a baseboard heater, on 440V a construction heater or similar resistive load.


How do you run 380 volt motor off 220 volt ac?

Short answer: No. (unless you like ruining motors) Longer answer: Not really, but there are some motors that can be re-wired so that instead of 440v they will run on 220v. However, this is not that common. Conclusion: Check the motor to see if it is dual-voltage on it's nameplate. If it is, you can re-connect it to work on 220v. If it is NOT a dual-voltage motor, you will absolutely ruin it if you connect it to 220v.


Panel box with a 3 pole 4 wire 440 volts 3 phase electric and you need to pull 220 volt single phase with 2 pole 3 wires how do you do it?

You can install a 220V single-phase transformer to step down the 440V three-phase supply to a 220V single-phase output. Connect the transformer's primary winding to the 440V three-phase source using the three poles and four wires. Then, connect the secondary winding to your 220V single-phase load using the two poles and three wires. Make sure to follow local electrical codes and regulations when performing this setup.


What happen to the 480v rated motoe when connected to 440v power?

Depending on the design of the motor, it may just run with less torque/hp. It might run slightly hotter as well, depending on the load.


Can a Volt motor run on Volt?

Short answer: No. (unless you like ruining motors) Longer answer: Not really, but there are some motors that can be re-wired so that instead of 440v they will run on 220v. However, this is not that common. Conclusion: Check the motor to see if it is dual-voltage on it's nameplate. If it is, you can re-connect it to work on 220v. If it is NOT a dual-voltage motor, you will absolutely ruin it if you connect it to 220v.


Can you get 120v single phase from 440 3 phase?

Yes, you can obtain 120V single-phase power from a 440V three-phase system using a transformer. By using a step-down transformer that reduces the voltage from 440V to 120V, you can safely access single-phase power. It's important to ensure that the transformer is correctly rated for the load and that all safety regulations are followed during installation. Always consult with a qualified electrician for any electrical work.


What happen to 440v motor running at 480v?

Depends on the motor. If it is a synchronous motor it will run too fast.


Why do you use single phase in house wiring?

bcoz we dont require too much voltage when working in home so in home generally 220v is preferred & in industries 3phase connection is used for heavy loads (440v)


What is the mean of 220-440 connection of 3 phase motor?

Star 220 v and delta 400 i star 58 percent only voltage applied delta 400v appliedAnswerThese figures do not represent three-phase, four-wire, system voltages, because if the line voltage were to be 440 V, then the phase voltage would be 254 V; or, if the phase voltage were to be 220 V, then the line voltage would be 381 V.


How many volts are 1.5 ton air conditioner unit?

As many as it was designed to be. Tonnage doesn't equate to voltage, and there are 12v automotive systems capable of such tonnage (particularly in tractor-trailer units). Could be 12v, 24v, 110v, 220v, 440v, etc.