A 2-Pole motor runs twice as fast as a 4-pole motor. The 2-pole motor has 2 windings at 180 degrees apart and the four pole motor has four windings at 90 degrees apart. The rotor tries to move from pole to pole with each half cycle of the AC current so the motor no-load speed for 60 cycle current is 2x3600/#poles. This is 1800 rpm for a 4-cycle motor and 3600 rpm for a 2-pole motor.
because its possible only where pole changing arrangements are given and pole changed motor draws more current then its actual pole which damages its windings.
Yes, the rotation of a shaded pole motor can be reversed. It is advisable to only attempt this on a small motor and if you have general mechanical and electrical knowledge. The simple and direct explanation is one has to flip the stator. To do this the motor must be disassembled to a point at which the rotor can be removed. Once removed, turn it end over end and reinstall. Done. Note that the bearing housing ends will likely have to be switched as well.
height of electric pole in India is 8m in residence area.
pole mortor ms 225-40
Basically tpn means the tripple pole + nutral protectin mbc .
electric and magnetic go hand in hand. One needed to produce other. Motor no magnetic pole, motor no work.
commutator
commutator
Relationship between motor rpm and no of poles
Pole pitch in a motor refers to the distance between the centers of two adjacent magnetic poles, typically measured in electrical degrees or physical distance. It is a critical factor in the design of electric motors, as it influences the motor's performance characteristics, such as torque and speed. The pole pitch is determined by the number of poles and the overall geometry of the motor. In essence, it plays a key role in how effectively the motor converts electrical energy into mechanical energy.
SAE 30 motor oil if the temperature is between 30 & 75°F.Colder use SAE 10 oil.Warmer use SAE 40 oil.
it is a 20 pole motor
A 3-pole motor has a smother torque curve.
Electric lines are on top of the pole to keep them out of the way.
A 2-pole motor has about 1.5 ft-lbs of torque per horsepower where a 4-pole motor has 3 ft-lbs of torque. also the speed of a 2-pole motor is twice that of a 4-pole motor. The speed of a motor is determined by: speed=(120 x freq)/no. of poles At 60 Hz, a 4-pole motor is about 1800 rpm where a 2-pole motor is 3600
shadded pole motor
There is hardly any voltage between the bird's two feet - or between the feet and other parts of the bird's body.