415v air circuit breaker acceptable value of 0.01 ohms and lessthan
400mega ohms acceptable....
30 micro ohms
This is a small electromagnet whose coil is in series with the relay contacts and whose contact is in parallel with them. The electromagnet is energized, closing its contacts in parallel with the relay contact as soon as the trip coil is energized, and drops out when the circuit breaker opens.
The Star-Delta control circuit diagram shows the delta contact and the main contact.
An open circuit has a break in it somewhere, so the circuit is not complete and electricity cannot flow. When you power off a light, for example, with an on/off switch, you open the circuit, turning off the light as desired. When there is an unwanted open circuit, for example from a damaged wire, the device or system is unpowered and cannot operate. A short circuit has some unwanted contact between points at different voltage levels, such as from hot to neutral or ground, or between positive and negative. When a short is in a circuit, electricity will take only that path of little or no resistance. The rest of the system is deprived of power, and the conductors feeding the point of the short will likely overheat or burn unless a fuse or breaker operates, creating now an open circuit.
A low voltage (less than 1000 VAC) circuit breaker for 15 A typically has a contact resistance of 0.01 Ohm or less.
You need to be more specific. Do you want a contact telling you if a circuit breaker is on? If that is your question, the answer depends on the model of the breaker.
In a vacuum breaker the moving contact and fixed contact are sealed inside a vacuum chamber. Electrons cannot flow in a vacuum, therefore as soon as the moving contact seperates from the fixed contact the arc meets an infinite resistance and is immediately extinguished. Because of this, the gap between the fixed and moving contacts when the breaker is open need only be a tiny amount.
400mega ohms acceptable....
If you have a burned circuit breaker in your home, it is important to turn off the power to that circuit immediately and contact a licensed electrician to inspect and replace the damaged breaker. Do not attempt to fix or replace the breaker yourself as it can be dangerous.
A ground fault circuit interrupter (GFCI) is a mini circuit breaker that responds to shorts or contact with water. It monitors the flow of electricity in a circuit, and if it detects a ground fault (such as water contacting the electrical system), it automatically shuts off the power to prevent electric shock.
30 micro ohms
A circuit breaker switch could spark due to a buildup of heat or a high level of current flowing through it. This can lead to arcing between the contacts inside the breaker, resulting in sparking. Additionally, loose connections or damage to the breaker can also cause sparking.
The circuit breaker may keep tripping immediately due to a short circuit, which occurs when a hot wire comes into contact with a neutral wire or ground wire. This causes a sudden surge of electricity, triggering the circuit breaker to trip for safety reasons.
If the circuit breaker is on but there is no power to the outlet, it could be due to a tripped circuit breaker, a faulty outlet, or a wiring issue. It is recommended to check the circuit breaker, reset it if necessary, and inspect the outlet for any visible damage or loose connections. If the problem persists, it may be best to contact a qualified electrician for further assistance.
132kv MOCB acceptable value of somthing 150 micro ohms.
Breaking Current: The r.m.s value of short circuit current at the instant of contact separation.