Basically . economiser is located in between exit of boiler and entry of air preheater. when the flue gases are coming out from boiler they take away a lot of heat. economiser utilize this heat from flue gases. and these heat is used to heat the feed water which is going to feed the bolier. hence by using economiser the coal consumption required to heat the feed water is reduced hence cost reduced.
500 MW Boiler is sub-critical Boiler which generates steam at pressure lower than the critical pressure ie below 221.2 kg/sqcm. where as the 660 MW boiler is super critical boiler which operates steam pressure above critical pressure.
Boiler mountings are different fittings and devices which are necessary for the operation and safety of a boiler .e.g. pressure gauge, safety valves , steam stop valve etc Normally these device are mounted over boiler shell .Boiler Accessories are auxilary plants or parts required for steam boilers for their proper operation and to increase efficiency of the boiler .e.g.feed pumps, super heater , economiser etc
what is boiler
In a coal-fired power station, a boiler burns coal to produce steam. The steam makes a turbine spin. The turbine drives an electricity generator. The electricity from the generator is converted to a higher voltage by a transformer. This higher voltage is to enable transmission over long power lines without losing too much energy. When it comes to reach our homes, it is then converted back into lower voltage by other transformers. Nuclear power stations are similar - instead of a coal-fired boiler, a nuclear reactor creates the steam. Wind turbines use the blades to turn the generator.
The amount of energy transferred from the steam is a function of the temperature difference between the input and output of the turbine. Also, superheating the steam ensures that there are no water molecules that can damage the turbine blades.
steam boiler
Economizer is an accessory of boiler that recovers the waste heat from the flue gas blown out of the boiler. Thus it actually "economizes" the operational cost or in other words, improves the efficiency of fuel utilisation in the boiler. The temperature of the flue gases ( the mixture of burnt fuel & air ) depends up on the steam pressure ( temperature more precisely ). Higher the steam pressure generated, the higher is the flue gas temperature. Economizer is a heat exchanger which exchanges heat between water ( which is fed in to the boiler ) & the flue gas. It means it increases the temperature of the feed water using the otherwise wasted heat of the flue gas. So the water entering the boiler has higher temperature compared to the one without this economizer. This higher temperature of water requires less amount of heat to generate steam so the operation becomes "economical". Similarly the economizer can also work to heat up the air entering the boiler through the flue gas heat, instead of heating the water.
If an economizer trips in a boiler system, it typically results in a shutdown of the economizer, which can lead to reduced energy efficiency and increased fuel consumption as the heat recovery process is interrupted. This may cause the boiler to operate at a higher temperature and pressure to compensate for the lost heat recovery, potentially triggering safety alarms and system protective measures. Additionally, the trip may lead to a decrease in steam production and could impact overall plant operations, necessitating immediate investigation and remedial actions to restore normal function.
deaerator is a device used to remove dissolved oxygen and carbondi oxide in boiler feed water. it causes scaling inside the boiler tubes and economizer also.
The flue gases, after leaving the main boiler and the superheater, will still be hot. The energy in these flue gases are used to preheat the already preheated feed water once more by means of the economizer. The economizer is a heat exchanger mounted in the first part of the chimney to improve the thermal efficiency of the boiler. In broad terms a 10°C increase in feed water temperature entering the boiler will give an efficiency improvement of 2% of last mentioned.
No. It utilizes steam to make it function. The boiler produces the steam.
Economizers (US), or economizers(UK/international), are mechanical devices intended to reduce energy consumption, or to perform another useful function such as preheating a fluid. The term economizer is used for other purposes as well. Boiler, power plant, and heating, ventilating, and air-conditioning (HVAC) uses are discussed in this article. In simple terms, an economizer is a heat exchanger.
Economizer is a device in which the waste heat of the fuel gases is utilized for heating the feed water.
What is used economizer in centrifugal chiller
One function: to safely heat water. Whatever the resulting hot water or steam is used for is not a function of the boiler, but the system it is connected to.
Since sufficient feedwater is not supplied into the economizer though the heat is absorbed from flue gas at the boiler start-up and low load operation, steaming may occur in the economizer. Therefore the economizer recirculation line is provided between the furnace downcomer and the economizer inlet feedwater piping. This line provides the recirculation flow between the drum, the downcomer and the economizer so as to prevent steaming in the economizer. Economizer recirculation valve is only opened at initial stage of the boiler start-up.
This is where water is turned into steam at high pressure, which is then fed into the steam turbine