It isn't necessarily (depending on your perspective). A three phase fault is a severe duty on generators, because all three phases are shorted. In solidly grounded systems a phase to ground fault could result in higher magnitude currents, which would be more difficult for a breaker to interrupt (so from the breaker's perspective, this would be more severe).

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why a 3 phase fault is more severe than other fault in transmission line?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Which is most severe fault in power system?

Three phase fault is the most severe.


What are symmetrical and unsymmetrical faults?

the fault in electrical transmission line which give rise to symmetrical fault current is called symmetric fault. e.g; L-L-L-G fault. the fault in transmission line which give rise to unsymmetrical fault current is called unsymmetrical fault.e.g; L-L , L-L-G , L-G fault to solve the unsymmetrical fault, the fault current can be represented by sum of the sequences--zero phase sequence , +ve phase sequence , -ve phase sequence. where L:line G:ground


Why are symmetrical faults more severe than unsymmetrical faults?

In power engineering, specifically three-phase power, a symmetric, symmetrical or balanced fault is a fault which affects each of the three-phases equally.In power engineering, specifically three phase power, an asymmetricor unbalanced fault is a fault which does not affect each of the three phases equally.for these reasons thus symmetrical faults are more severe than the former. In power engineering, specifically three-phase power, a symmetric, symmetrical or balanced fault is a fault which affects each of the three-phases equally.In power engineering, specifically three phase power, an asymmetricor unbalanced fault is a fault which does not affect each of the three phases equally.for these reasons thus symmetrical faults are more severe than the former.


What is symmetrical fault in transmission line?

A symmetrical fault is a fault where all three phases are experiencing the same thing. This is also called a three phase fault, since all three phases are involved.


What are the types of transmission line faults?

these are the faults that occur in transmission line: 1. line to line fault 2. line to ground fault-this is the most common fault that occurs in tr. line(75%) 3. double line to ground fault 4. triple line to ground (or) 3 phase fault- this is the most serious and dangerous fault that occurs in transmission line.(but rarely occurs)


What are the types of faults in ehv transmission lines?

The three types are Line to ground faults line to line fault double line to ground fault three phase line to ground fault


How do you calculate 3 phase earth fault loop?

You can't have a three phase earth fault, you can have a phase to phase or a phase to earth fault. If you want the potential phase to earth fault current it will be your voltage times your impedance. If you want the phase to phase potential fault current then you should just double the above result.


What is phase to ground fault?

There will a only one phase on home electricity.AnswerThere is no such thing as a phase-to-phase-to-ground fault'; the correct term is 'line-to-line-to-ground fault. It occurs when two or more line conductors make contact with each other and to ground; for example, when a JCB accidentally cuts through a three-phase cable.


How is a IDMT relay used to give protection against a phase to earth fault a phase to phase fault on a feeder?

As with any IDMT relay the higher the fault current the quicker the trip time.


What is a disconnect installation fault?

I have never heard a fault type referred to as a "disconnect installation fault". In general there are a few types of faults - phase to ground or ground faults, phase to phase, phase to phase to ground, three phase, and three phase to ground. I'm guessing what you're referring to is a fault on a disconnect switch. Disconnects are used to isolate equipment. When a disconnect faults, it usually faults to ground.


Can an electrical short be caused a phase to a phase?

It could be a phase to phase, ph to neutral or earth fault. In single ph wiring ph to ph exhibits no short ckt faultAnswerYes, but you have got the terminology wrong. There is no such thing as 'phase-to-phase', the correct term being 'line-to-line'. So you can have a short circuit as a result of a line-to-line fault, a line-to-neutral fault, or a line-to-earth fault.


What is a fault record?

fault records gives complete information about a fault,i. fault current magnitude,type of fault,fault phase details,etc.with time stamping.