answersLogoWhite

0

Busbars are not necessarily rectangular. Those used in substation compounds are frequently tubular in construction.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Electrical Engineering

How can you calculate the copper bus bar according to the amp?

To obtain the amp of the copper bus bar, multiply the width of the bus bar by the thickness of the bus bar to obtain the current carrying capacity of the bus bar.


What are the types of bus bar arrangements?

Single bus is used in smaller, less important substations. A fault on the bus requires tripping of all lines into the bus. When higher redundancy is necessary, ring and breaker and 1/2 schemes are used. These are the three most common.


Difference between bus bar and bus duct?

Bus bars are actually simple conductor strips of copper using for connection between one system to another.for example transformer to panel. bus ducts are enclouser of that bus bar


What is the difference between a 200 amp bus bar and a 150 amp bus bar?

The primary difference between a 200 amp bus bar and a 150 amp bus bar lies in their current-carrying capacity. A 200 amp bus bar can safely handle a maximum load of 200 amps, making it suitable for larger electrical systems, while a 150 amp bus bar is limited to 150 amps. This difference affects their applications; a 200 amp bus bar is typically used in larger service panels or commercial settings, whereas a 150 amp bus bar may be adequate for smaller residential systems. Additionally, the physical size and material specifications may vary to accommodate the different current ratings.


What is double busbar arrangement?

Double bus bar is related to power control center (PCC). PCC is the main LT power distribution in any industrial establishment or large residential complex too. It basically an electrical panel with required number of incomer feeders and outgoing feeders. Power source like state power or captive power provide the incomers and outgoing feeders cater to the down stream power panels for further distribution( to MCC). Any PCC has one or more incomer and one or more outgoing feeder and bus isolators depending on the requirement. This PCC needs to have a bus bar to which the incomer gets connected and feeds the power to the bus and the outgoing feeders are connected to the bus bar to deliver the power down stream. This bus bar can be single bus bar system or double bus bar system. In a double bus bar system the two different power sources are connected to two different bus. Say one bus is for DG set power another bus is for SEB power. Both the buses can be charged simultaneously and can feed any outgoing feeders. The out going feeder have flexibility of getting the power either of the buses, but not simultaneously from both the buses. Double bus bar is more expensive compared to single bus bar system but more flexible, reliable.

Related Questions

How can you calculate the copper bus bar according to the amp?

To obtain the amp of the copper bus bar, multiply the width of the bus bar by the thickness of the bus bar to obtain the current carrying capacity of the bus bar.


What is the bus bar size for 6000A?

5-6x150 Cu. BUS BAR PER PHASE


What are the types of bus bar arrangements?

Single bus is used in smaller, less important substations. A fault on the bus requires tripping of all lines into the bus. When higher redundancy is necessary, ring and breaker and 1/2 schemes are used. These are the three most common.


What is a buss bar?

A 'bus bar' (not 'buss') is usually a strip of heavy-duty rectangular-section copper conductor, at line, neutral, or earth potential, to which a number of individual circuit conductors can be connected. It provides a common point of connection for several circuit conductors. The origin of the word, 'bus', comes from 'omnibus' -which means 'providing for many things at once'.


Bus Bar?

Its a switch


What does the term 'bus bar' refer to?

The term "bus bar" refers to a strip of bar of brass, aluminum, or copper. This strip of bar conducts electricity with a distribution and switch board.


Where is the place of main bar in rectangular footing?

in a rectangular foundation long bars to be in bottom and short bar to be on top of long bars, where as in slab opposite to the foooting bars


How do you convert bus bar to amp?

Bus bar is a physical component that carries the current. AMP is unit of current. They can not be converted


Why the impedance of infinite bus bar is zero?

...because it is an infinite bus bar, meaning it can supply infinite current. By Ohm's law, since the voltage at the bus bar is fixed, to have infinite current, you must have a zero impedance.


Difference between bus bar and bus duct?

Bus bars are actually simple conductor strips of copper using for connection between one system to another.for example transformer to panel. bus ducts are enclouser of that bus bar


What is the difference between a 200 amp bus bar and a 150 amp bus bar?

The primary difference between a 200 amp bus bar and a 150 amp bus bar lies in their current-carrying capacity. A 200 amp bus bar can safely handle a maximum load of 200 amps, making it suitable for larger electrical systems, while a 150 amp bus bar is limited to 150 amps. This difference affects their applications; a 200 amp bus bar is typically used in larger service panels or commercial settings, whereas a 150 amp bus bar may be adequate for smaller residential systems. Additionally, the physical size and material specifications may vary to accommodate the different current ratings.


What are the conditions for Synchronization of three phase alternator and bus bar?

voltage of incoming machine should be same as that of bus bar voltage