answersLogoWhite

0

What else can I help you with?

Continue Learning about Engineering

Difference between TP and TPN isolator?

The main difference between the two is that a TP isolator is only a "triple pole" isolator. A TPN isolator is a "triple pole" and neutral isolator.


What is operating coil of differential relay?

My understanding is that on most (if not all) differential relays, there are currents coming in from both sides of the operating coil. These currents should cancel out, or in reality, nearly cancel out. Therefore, the effective current in the operating coil is zero. When the net current in the operating coil is not zero, the relay trips. There are instances when you don't want the relay to trip though. Therefore, the operating coil works together with a restraint coil. (Well probably 2 restraint coils.) The relay will trip if the operating coil's current must exceed the restraint coil's current by a certain amount.


What is the difference between isolator and circulator?

Isolator is something which blocks current or heat. Where as Circulator is something through which heat and electricity can pass.


Why two shunt trip coil joined in parallel in circuit breaker?

the C.B operation depends upon relay senses. in realy their is trip coil. when ever fault occurs then change in c.t occures[current varies] due to that secondary current in c.t changes then magnetising field of trip coil is varies and then relay contacts open then c.b contacts open..........this is the impotance of TRIP COIL


Difference between on load and off load isolator?

In electrical system load means circuit carrying current . Isolator is device which make on ( Connect ) and off ( Disconnect ) of circuit from supply. When load is ON means carrying current and required to disconnect from supply , than is called on load isolation.Here required on load isolator. When load is OFF means not carrying current and required to disconnect from supply , than is called off load isolation.Here required off load isolator. On load isolators design is more precise than off load isolator because while isolating load during ON states create heavy sparking and transient voltage spikes.

Related Questions

What is the symbol for trip coil?

coil


What are all the parts to change the struts on Toyota Avalon 1998?

Strut mount, coil spring, coil spring isolator, rubber dust boot.


What are the functions of shunt trip coil in ACB?

shunt trip coil used to trip the breaker automatically or manually.


What is tp isolator?

TP isolator means triple Pole Isolator.


Difference between TP and TPN isolator?

The main difference between the two is that a TP isolator is only a "triple pole" isolator. A TPN isolator is a "triple pole" and neutral isolator.


What voltage feeds the coil on a shunt trip breaker?

220V


When was Isolator - EP - created?

Isolator - EP - was created on 2006-09-26.


When was Oscillation Isolator created?

The Oscillation Isolator was created in 2018. It is a device designed to reduce vibrations in mechanical systems.


What is the rubber piece inside of some coil springs for?

The rubber piece inside some coil springs is called a coil spring isolator. It is used to reduce noise and vibrations by providing cushioning between the coils of the spring. It also helps to prevent metal-to-metal contact, which can reduce wear and tear on the spring.


What are 4things needed to make an electromagnet?

* A conductor that can be shaped into a coil. Copper wire, for example. * An isolator that keeps the conductor's threads isolated from each other, thus forcing the current through all loops of the coil. * An electric current through the coil. * Typically, but not necessarily, a ferrite core to bundle the magnetic field.


Why two trip coil require in breaker?

Having two trip coils in a circuit breaker provides redundancy and increased reliability. If one coil fails, the other can still operate the breaker. Additionally, using two trip coils may allow for greater flexibility in the control and operation of the breaker.


What is the difference between a line isolator and a bus isolator?

If I'm interpreting the question accurately, a "line isolator" is an insulating standoff for transmission or distribution cable. A bus isolator is an insulating standoff for tubular or bar bus as is normally seen in a substation switching yard.