You should look at the transformer vector diagram, or the type of transformer will tell you (something like YnD1, for example). If it's a Y/Y type transformer, the phase angle will be zero. If it is a D/D, it will be zero. If it's a Y/D, or D/Y, it could be +30, -30 (usually). I have seen a few strange cases where a Y/D was +150 degrees.
The difference between the two transformers is the coil ratios between the primary and secondary windings. A transformer that increases voltage from primary to secondary has more secondary winding turns than primary winding turns and is called a step-up transformer. Conversely, a transformer with fewer secondary windings does just the opposite and is called a step-down transformer.
the difference between a step up transformer and a step down transformer is that, in a tsep up transformer, the voltage secondary is greater than the primary side but in a step down transformer, the voltage secondary is lesser than the primary side
The secondary current of a transformer is determined by the load and the secondary voltage applied to that load, and this, in turn, will determine the primary current by the inverse of the turns ratio. However, if you are asking about a transformer's rated secondary and primary currents, then you need to divide the transformer's apparent power rating (expressed in volt amperes) by the rated secondary and primary voltages respectively.
It depends on the turns ratio between the primary and the secondary. If the ratio were 10:1, a step-down transformer, for instance, the current in the secondary would be about 50A. If it were 1:10, a step-up transformer, however, the current in the secondary would be about 0.5A.AnswerThe primary current doesn't determine the secondary current. The secondary current is entirely-dependent on the secondary voltage and the impedance of the load. It is this secondary current that the determines the primary current. So you should be asking, "What value of secondary current would result in a primary current of 5.0 A?"
primary and secondary coilsAnswerPrimary and secondary windings.
The primary current of a transformer depends upon the secondary current which, in turn, depends upon the load supplied by the transformer. There is not enough information in the question to determine the rated primary and secondary currents of the transformer.
The difference between the two transformers is the coil ratios between the primary and secondary windings. A transformer that increases voltage from primary to secondary has more secondary winding turns than primary winding turns and is called a step-up transformer. Conversely, a transformer with fewer secondary windings does just the opposite and is called a step-down transformer.
No, the primary winding VA does not necessarily equal the secondary winding VA when a transformer is loaded. The power output on the secondary side may differ from the power input on the primary side due to losses such as resistive and core losses in the transformer. The transformer's efficiency will determine how close the VA on the primary winding is to the VA on the secondary winding.
The primary and secondary windings of a mutual transformer are electrically isolated, and should have 'infinite' resistance between them when measured appropriately (which depends on voltage ratings of the windings).
The voltage phase shift between primary and secondary connections in a transformer is 180 electrical degrees.
the difference between a step up transformer and a step down transformer is that, in a tsep up transformer, the voltage secondary is greater than the primary side but in a step down transformer, the voltage secondary is lesser than the primary side
The secondary current of a transformer is determined by the load and the secondary voltage applied to that load, and this, in turn, will determine the primary current by the inverse of the turns ratio. However, if you are asking about a transformer's rated secondary and primary currents, then you need to divide the transformer's apparent power rating (expressed in volt amperes) by the rated secondary and primary voltages respectively.
It depends on the turns ratio between the primary and the secondary. If the ratio were 10:1, a step-down transformer, for instance, the current in the secondary would be about 50A. If it were 1:10, a step-up transformer, however, the current in the secondary would be about 0.5A.AnswerThe primary current doesn't determine the secondary current. The secondary current is entirely-dependent on the secondary voltage and the impedance of the load. It is this secondary current that the determines the primary current. So you should be asking, "What value of secondary current would result in a primary current of 5.0 A?"
The ratio of the primary voltage to the secondary voltage is proportional to the ratio of windings. So if the primary voltage is 120 volts and the secondary is 240 volts there are twice as many turns in the secondary.AnswerAs the previous answer says, you can work out the turns ratio of a transformer, but knowing the primary and secondary voltages will not help you determine how many turns are on each winding.
The primary current on a loaded transformer depends on the secondary current, which is determined by the load. So, if you know the secondary load current, then you can use the turns ratio of the transformer to determine the primary current:Ip/Is = Ns/Np
primary and secondary coilsAnswerPrimary and secondary windings.
The 'input' side of a transformer is called its 'primary' side, whereas the 'output' side is termed its 'secondary' side. The ratio of its secondary to primary voltage is equal to the ratio of the number of turns in the secondary windings to the number of turns in the primary winding. So if, for example, a transformer's secondary winding has twice as many turns as its primary winding, then the secondary winding will produce twice the voltage applied to the primary winding.