You start with a normal one way circuit consisting of a three phase contactor and an three phase overload in series for the forward circuit. Then you add the reverse contactor in parallel with the forward contactor but with line one and line two crossed over i.e. when the reverse contactor is made, line one of the supply will be connected to line two of the motor and line two of the supply to line one of the motor. The control circuit must also be interlocked to prevent forward and reverse being energized at the same time.
You never need a starter for a three-phase motor.
There are two alternate methods depending on whether the motor is single phase or three phase. On a single phase motor, reverse either the start winding coil lead or the run winding coil lead but not both. This action will reverse the motor's rotation. On a three phase motor, interchanging any two of the three coil leads will reverse the motor's rotation.
A three-phase meter can be used for single phase while the reverse is not the case.
The reverse running of a three phase meter is possible when one of the meter's two potential coils fails. This is a problem found typically on a Delta service. A three phase meter in this condition is damaged and will report lower energy use than actual.
yes
motor is designed to operate in forward and reverse direction for the purpose of elevator. Phase sequence protection is not required.
You never need a starter for a three-phase motor.
A three-phase forward reverse starter can be effectively used in industrial applications where electric motors need to run in both forward and reverse directions, such as conveyor belts, pumps, and cranes. It allows for quick and easy control of the motor's direction of rotation without the need for manual switching of power connections.
There are two alternate methods depending on whether the motor is single phase or three phase. On a single phase motor, reverse either the start winding coil lead or the run winding coil lead but not both. This action will reverse the motor's rotation. On a three phase motor, interchanging any two of the three coil leads will reverse the motor's rotation.
A three-phase meter can be used for single phase while the reverse is not the case.
If a three phase motor in running in reverse, then one of the phases is reversed, plain and simple. If the wiring is correct at the motor, perhaps the phase reversal occurred someplace else.
Switch two of the three wires.
Remove the cables from the starter. Remove the three retaining bolts from the starter. The starter will come out. Reverse the process to install the new starter.
The reverse running of a three phase meter is possible when one of the meter's two potential coils fails. This is a problem found typically on a Delta service. A three phase meter in this condition is damaged and will report lower energy use than actual.
Three phase motors are controlled by a device called a starter. The starter allows the motor's supply voltage to be applied to and removed from the motor. These types of starters coil's can be controlled with usually a lower voltage that can be remotely controlled.
yes
A starter is unnecessary because the stator produces a rotating magnetic field.