only the single phase monitored at which it installed
No, three phase motor overloads just monitor the motor's lines for an overload. Once detected the circuit holding the magnetic starter in will drop out and take the motor off line.
due to the extension of loads they are using the relays for protection.........
If you are describing a circuit breaker then its electromagnetic trip component will operate in the event of a line*-to-ground (*not 'phase'!) short circuit. The thermal overload component will only operate in the event of a sustained overload.
The Allen-Bradley 193-EF1A overload relay functions by monitoring the current flowing through the motor circuit. It uses thermal and electronic sensing to detect overload conditions, which occur when the current exceeds a preset limit for a specified duration. When an overload is detected, the relay opens its contacts to interrupt the motor circuit, thereby protecting the motor from damage. The relay can be reset manually or automatically, depending on the specific model and configuration.
Yes, when using a three phase contactor on single phase, the three phase overload block can be used. The wiring of the contactor consists of taking L1 of the supply and connecting it to L1 of the contactor. The load is connected to T1 on the bottom of the overload block. L2 of the supply is taken to L2 of the contactor. Instead of connecting the T2 to the load, the conductor is taken back to the top and connected to the contactor in position L3. The other side of the load is connected to T3 on the bottom of the overload block. The overload block has three N.C. contacts, one for each leg of L1, L2 and L3. These three contacts are wires in series to the stop - start circuit. Years ago on old schematic diagrams these contacts used to be placed on the up stream side of the magnetic starter's coil. When the overloads tripped the voltage was left on the control circuit which was found to be dangerous for trouble shooting. Now the overload contacts are positions on the beginning of the start- stop circuit so that when a overload trips, the whole stop - start circuit becomes de energized.
overload model no Ke-FKR4(D)
No, three phase motor overloads just monitor the motor's lines for an overload. Once detected the circuit holding the magnetic starter in will drop out and take the motor off line.
due to the extension of loads they are using the relays for protection.........
A device with an overload protection used to control a motor is an Overload Relay.
In a Wye/star system the overloads look at the phase to neutral/ground current; not phase to phase current. Which is always calculated as root three or 1.73205.............etc. Therefore the overloads have to be set to the phase to neutral/ground current.
How Negative phase sequence relay work
If you are describing a circuit breaker then its electromagnetic trip component will operate in the event of a line*-to-ground (*not 'phase'!) short circuit. The thermal overload component will only operate in the event of a sustained overload.
The Allen-Bradley 193-EF1A overload relay functions by monitoring the current flowing through the motor circuit. It uses thermal and electronic sensing to detect overload conditions, which occur when the current exceeds a preset limit for a specified duration. When an overload is detected, the relay opens its contacts to interrupt the motor circuit, thereby protecting the motor from damage. The relay can be reset manually or automatically, depending on the specific model and configuration.
Protects the flasher relay from an overload or short.
Any value over .65kA will be classed as an overload.
3
Dashpot Overload Relay