A power line carries electrical current from the power source to the load, delivering energy for use in homes and businesses. In contrast, a neutral line provides a return path for the current, completing the electrical circuit and ensuring safety by stabilizing the voltage. While the power line typically carries high voltage, the neutral line is grounded to prevent electrical shock and maintain a balanced system.
There is never a switch installed in a neutral line.
The formula to use is, phase voltage /1.73 = phase to neutral (ground) voltage.CommentThere is no such thing as a 'phase to phase', or 'phase to neutral' voltage. The correct terms are 'line to line' and 'line to neutral'. So the above answer should read: line voltage/1.73= line to neutral voltage = phase voltage.
In Europe, low-voltage three-phase distribution is by means of a four-wire system (three line conductors and a neutral) supplied from a wye-connected transformer secondary. In North America, low-voltage is supplied from a delta-connected transformer secondary, one phase of which is centre-tapped and earthed (grounded). The single-phase supply to residences is then supplied by that particular phase, giving 240 V line-to-line and 120 V line-to-neutral. You can tell if you have a delta power when the phase voltage is equal to the line voltage and that you have a star power when the phase voltage =root 3(THE LINE VOLTAGE).
There are situations where the secondary of a transformer is not grounded and the neutral is not connected to the neutral of the primary. This can cause a potential shock hazard so the secondary side needs to be protected.
The line-to-neutral (not 'phase-to-neutral'!) voltage on a 400V 3-Phase wye-connected system is 230V.Line voltage is the voltage as measured between any two (2) line conductors (hence its name!). Line voltage is often referred to as the 'line-to-line voltage'.Phase voltage is the voltage as measured between any single line and neutral. Phase voltage is often referred to as a 'line-to-neutral' voltage."400V" on a 400V 3-Phase wye-connected power supply indicates its line voltage. Line voltage in a wye system is always the phase voltage multiplied by the square-root of "3" (1.732) and reflects the vector sum of two individual phase voltages present in a three phase system.Thusly, if the line voltage is "400V", then the phase voltage is 400V divided by the square-root of "3" (1.732), which is 230V.Examples of this for North American power systems are 120/208V, 277/480V and 347/600V. Examples for other areas of the world are 220/380V, 230/400V and 240/415V.
line to line or line to neutral is the only way to use power line to ground if a FAULT current in the ground is a problem that needs to be corrected, an insulation fault
It is the same as phase to neutral. As the neutral is earthed at the electricity suppliers transformer.
You said it yourself. The power is from line to line, or more correctly, from hot to hot. There is no neutral involved.
If phase and neutral get reversed in a power line, electrical appliances may malfunction, and there is a risk of electrical shock to users. To rectify this issue, you must immediately shut off the power supply and contact a qualified electrician to correct the wiring configuration. Reversing phase and neutral can be dangerous and should be addressed promptly to prevent any potential hazards.
There is normally no voltage on the neutral line because the neutral line is grounded. However, and this is always important, do not assume that neutral is grounded, nor that there is not an elevated voltage on neutral or ground due to a possible ground fault.
There is never a switch installed in a neutral line.
With a three-phase system the voltage quoted is the line-to-line voltage between any two live lines. To find the line-to-neutral voltage divide by 1.732 which is sqrt(3). The power supplied from each phase is the current times the line-to-neutral voltage (times the power factor if less than 1). To find the total power when the currents are equal, multiply by 3.
Black is the hot side of the line, white the neutral side, green (or rarely bare) wire is the ground.
The purpose of the load line neutral in an electrical circuit is to provide a return path for the current flowing from the load back to the power source, ensuring proper functioning of the circuit and safety of the electrical system.
You said it yourself. The power is from line to line to line, or more correctly from hot to hot to hot, in a delta configuration. There is no neutral involved.AnswerThe phasor sum of the three line currents is always zero, so there is no requirement for a neutral conductor. Expressed another way, at any instant in time, if you were to add the three line currents together, taking their directions into account (some would be flowing towards the load; others away), then the answer would be zero.
The neutral line in home electricity completes the circuit by providing a return path for current to flow back to the electrical source. It helps balance the electrical load and provides a reference point for voltage measurements. Without a neutral line, the circuit would not function properly and could pose safety risks.