answersLogoWhite

0

Operating coil cut-off in a trip relay refers to the mechanism that interrupts the power supply to the relay's operating coil once the relay has actuated. This cut-off prevents the coil from overheating and ensures that the relay remains in its tripped state until it is manually reset or the fault condition is cleared. By removing power from the coil, the relay can maintain its position without continuous energy consumption, improving reliability and efficiency.

User Avatar

AnswerBot

1mo ago

What else can I help you with?

Continue Learning about Engineering

What is operating coil of differential relay?

My understanding is that on most (if not all) differential relays, there are currents coming in from both sides of the operating coil. These currents should cancel out, or in reality, nearly cancel out. Therefore, the effective current in the operating coil is zero. When the net current in the operating coil is not zero, the relay trips. There are instances when you don't want the relay to trip though. Therefore, the operating coil works together with a restraint coil. (Well probably 2 restraint coils.) The relay will trip if the operating coil's current must exceed the restraint coil's current by a certain amount.


What is percentage bias relay?

This is basically a differential relay that contains an additional restraining coil with the operating coil connected at its midpoint used to prevent the unnecessary pick up of the relay.


What is the purpose of a coil clearing contacts?

Coil clearing contacts are used in electrical relay systems to ensure that the relay coil is de-energized and to facilitate the proper operation of the relay. When the relay coil is energized, these contacts help clear any residual current or voltage from the coil, preventing unintended activation or malfunction. This is crucial for the reliable operation of the relay, especially in applications requiring precise control and safety. Ultimately, coil clearing contacts enhance the overall performance and longevity of relay systems.


What would read across a relay coil?

Across a relay coil, you would typically measure the coil's rated voltage, which is the voltage required to energize the coil and activate the relay. This voltage can vary depending on the relay's specifications, commonly ranging from 5V to 240V DC or AC. When the coil is energized, it creates a magnetic field that closes the relay contacts, allowing current to flow through the connected circuit. If you measure the voltage while the relay is de-energized, you would expect to see zero volts across the coil.


Can you directly connect 12 V DC 10 A relay to 230 V AC Supply main line?

Yes you can .connect the 230 volt capacitor series with the relay coil.AnswerIf you are referring to the operating coil, then the answer is of course not, as you will be subjecting the coil to nearly 20 times its rated voltage! If you are referring to the contacts, then you need to check the nameplate data for the relay to find out what voltage the contacts are designed to operate at.

Related Questions

What is operating coil of differential relay?

My understanding is that on most (if not all) differential relays, there are currents coming in from both sides of the operating coil. These currents should cancel out, or in reality, nearly cancel out. Therefore, the effective current in the operating coil is zero. When the net current in the operating coil is not zero, the relay trips. There are instances when you don't want the relay to trip though. Therefore, the operating coil works together with a restraint coil. (Well probably 2 restraint coils.) The relay will trip if the operating coil's current must exceed the restraint coil's current by a certain amount.


What is percentage bias relay?

This is basically a differential relay that contains an additional restraining coil with the operating coil connected at its midpoint used to prevent the unnecessary pick up of the relay.


Where is coil relay on 1986 ford eco van?

There is no such thing as a coil relay.


What is a relay coil?

Most relays have an internal electromagnetic coil that is energized when the relay is activated.


What is a control relay coil?

Most relays have an internal electromagnetic coil that is energized when the relay is activated.


What could cause a relay coil resistance to be lower than specification?

A short within the relay coil itself.


What is the purpose of a coil clearing contacts?

Coil clearing contacts are used in electrical relay systems to ensure that the relay coil is de-energized and to facilitate the proper operation of the relay. When the relay coil is energized, these contacts help clear any residual current or voltage from the coil, preventing unintended activation or malfunction. This is crucial for the reliable operation of the relay, especially in applications requiring precise control and safety. Ultimately, coil clearing contacts enhance the overall performance and longevity of relay systems.


Why would an electrical relay hum?

The reason the relay humms or buzzes is that the pole faces on the relay are not aligning properly. This could be a result of the relay being out in the weather and developing a coat of rust on it. If the relay stops the noise when given a tap on its side then that is the cause. The other cause could be from a broken shorted turn. The use of laminations in an ac relay reduces the heating due to eddy currents. In addition, a copper strap or ring (called a shorted turn) is placed near the end of the pole piece of an ac relay to reduce chatter during operation. Because the ac is going through a peak, dropping to zero, going through a peak in the opposite direction, and then dropping to zero again during each complete cycle, the coil tends to release the armature each time the current drops to zero and attracts the armature each time it reaches a peak. The shorted turn acts as the secondary of a transformer, the primary of which is the relay operating coil. The current in the shorted turn is out of phase with the current of the operating coil because the copper ring has low-inductive reactance. Thus, when the operating coil flux is zero, the flux produced by the shorted coil is different from zero, and the tendency of the relay to chatter is reduced.


What would read across a relay coil?

Across a relay coil, you would typically measure the coil's rated voltage, which is the voltage required to energize the coil and activate the relay. This voltage can vary depending on the relay's specifications, commonly ranging from 5V to 240V DC or AC. When the coil is energized, it creates a magnetic field that closes the relay contacts, allowing current to flow through the connected circuit. If you measure the voltage while the relay is de-energized, you would expect to see zero volts across the coil.


What is the definition of negative phase sequence relay?

negative phase relay is used for the protection against unbalanced condition in a basic model a wheastones bridge is used with the operating coil connected across it.when any fault occurs unbalance will occur in the system and the relay will operate


What is interposing relay?

It is a relay that has two states. in one state a set of contacts will make or break. In the other state the other set of contacts will make or break. One coil operating two sets of common, normally open, normally closed. each set of contacts will change states when the coil is momentarily energized.


Can you directly connect 12 V DC 10 A relay to 230 V AC Supply main line?

Yes you can .connect the 230 volt capacitor series with the relay coil.AnswerIf you are referring to the operating coil, then the answer is of course not, as you will be subjecting the coil to nearly 20 times its rated voltage! If you are referring to the contacts, then you need to check the nameplate data for the relay to find out what voltage the contacts are designed to operate at.