How many amps does a 50 horse power electric motor use?

Need to know the voltage of the motor.


Is it okay to connect 50 hz to 60 hz?

Assuming that you are referring to a piece of equipment designed for 60-hz power being connected to a 50-hz power line (common overseas), It depends on the application. If the load is a DC power supply, they are often rated for both 50 and 60 hz. If the load is a motor made for 60 hz, for example, it will run about 17% slower at 50 hz than at 60 hz due to the design of induction motors, and at higher current because of lower inductive reactance. If the load is fluorescent lighting, it may display an annoying flicker, and the ballasts will probably die an early death. If the load is transformer-powered, you'll have the same current problems as you get with the motor. OTOH, if you want to connect a 50-hz load to a 60-hz supply, it has its own issues. E.g., the motor will run faster and cannot be loaded as heavily. Best bet: research to see if the piece of equipment is rated for both frequencies.


What is 50 hz motor?

It is a motor where the frequency of the AC voltage is 50 cycles per second. In U.S.A. 60 Hz is standard. 50 Hz would be overseas.


Can a 4 Pole 50 Hertz 440 V induction motor run at 900 rpm?

No. With the values given the motor will run at 1500 RPM. RPM = Hz x 60 x 2/# of poles. The only way the motor can be run at that speed is by using a VFD as its source of power.


If a load takes 50 kW at a power factor of 0.5 lagging Calculate the apparent power and reactive power?

If a load takes 50 kW at a power factor of 0.5 lagging calculate the apparent power and reactive power Answer: Apparent power = Active power / Power Factor In this case, Active power = 50 kW and power factor = 0.5 So Apparent power = 50/0.5 = 100 KVA

Related Questions

12v Motor?

form_title= 12v Motor form_header= Buy a new 12v motor with help from the pros. What battery do you use to power your motor?*= _ [50] When did you last change your oil? *= _ [50] Has your motor quit recently?*= () Yes () No


How many amps does a 50 horse power electric motor use?

Need to know the voltage of the motor.


Can you operate a motor of 575 v 60 Hz with a power supply of 575v 50 Hz?

Operating a motor designed for 60 Hz on a 50 Hz power supply can lead to issues such as overheating and reduced efficiency. It's recommended to use a motor that matches the frequency of the power supply for optimal performance and to prevent damage to the motor. In this case, it's best to avoid operating a 575 V 60 Hz motor on a 575 V 50 Hz power supply.


How much hp is a 4 stroke motor?

it would be around 50-60 horse power


Is it okay to connect 50 hz to 60 hz?

Assuming that you are referring to a piece of equipment designed for 60-hz power being connected to a 50-hz power line (common overseas), It depends on the application. If the load is a DC power supply, they are often rated for both 50 and 60 hz. If the load is a motor made for 60 hz, for example, it will run about 17% slower at 50 hz than at 60 hz due to the design of induction motors, and at higher current because of lower inductive reactance. If the load is fluorescent lighting, it may display an annoying flicker, and the ballasts will probably die an early death. If the load is transformer-powered, you'll have the same current problems as you get with the motor. OTOH, if you want to connect a 50-hz load to a 60-hz supply, it has its own issues. E.g., the motor will run faster and cannot be loaded as heavily. Best bet: research to see if the piece of equipment is rated for both frequencies.


What would be the gas oil mixture for a 1965 Evinrude 40 horse power outboard motor?

50 to 1


What would be the gas oil mixture for a 1981 Evinrude 35 horse power outboard motor?

50:1


What would be the gas oil mixture for a 1965 Evinrude 18 horse power outboard motor?

50 to 1


How many amps does a78kw 415volts 50 hz motor take?

To calculate the amperage, use the formula: Current (A) = Power (W) / (Voltage (V) * √3 * Power factor) Assuming a power factor of 0.8 for a typical motor, the current draw for a 78kW 415V motor at 50Hz would be approximately 111.58A.


What is the meaning of motor of 50 horsepower?

Horsepower is a unit of power. For an electric motor, the horsepower is defined as 746 watts of power. For a 50 horsepower motor, that translates to 37.3 KW.The origin of the term came from an attempt to equate the power of a horse versus the power of a steam engine. Early ratings came out to be about 33,000 foot-pounds per minute or about 550 foot-pounds per second. Today, the term varies, depending on the application. For electric motors, again, it is 746 watts.


What spark plug does 50 horse power outboard motor take?

The required spark plug for a 50 hp outboard engine would depend on the make, and year model of the engine.


Canoe Motor Mount?