Why there is power dissipation in field winding whereas it is negligible in armature winding?

There are losses associated with both, but I don't think that's what you're getting at. The power applied to the field winding, typically on the rotor of a generator, is used to turn the field winding into an electromagnet; This electromagnet is forced to spin, which induces a current in the armature windings. This induced current is the power output from the generator. So a little power is lost/used in the field winding to convert the kinetic energy from the turbine into electric energy.


What are field windings and armature windings in a dc motor and generator?

generators have two types of winding , * at armature also called armature winding( winding around shaft , we can say), which is the moving part. note that armature also consists of magnets along with windings. hence produces field arount it. * and at stator also called field winding, because when armature rotates its flux(field) is cutted by the stator windings and produces mutually induced e.m.f in it( in stator windings off course) causing current to flow. this current also produces some electric field around it which is in return cutted by the armature windings hince a little amount of e.m.f ( also called back e.m.f) produced in armature due to stator winding current. know this current in armature (due to back e.m.f produced by stator winding) produces additional field , hence causing more current in stator winding. this is the reason that why stator windings are called field winding( as they cause electric field of armature stronger and cause more current in output). note that out put is taken from the stator windings in generators.


What is steam power plant function?

doing porno is good


Will running a motor backwards generate power?

No. Motors can be run in either direction, clockwise or counter clockwise. However, mechanically spinning an electric motor will generate electric power.


What is three phase winding?

they are winding wound in such a way that they deliver three times the power

Related Questions

Why there is power dissipation in field winding whereas it is negligible in armature winding?

There are losses associated with both, but I don't think that's what you're getting at. The power applied to the field winding, typically on the rotor of a generator, is used to turn the field winding into an electromagnet; This electromagnet is forced to spin, which induces a current in the armature windings. This induced current is the power output from the generator. So a little power is lost/used in the field winding to convert the kinetic energy from the turbine into electric energy.


What is the function of a primary windding?

I assume we're talking about transformers here. The primary winding carries the input (alternating) current to the transformer. The (alternating) magnetic field it generates passes through the secondary winding and induces an (alternating) voltage in that which can be uses to power up other circuits.


What is the difference between a field winding and an armature winding in any machine?

In electrical machines such as motors and generators, the field winding is responsible for producing a magnetic field within the machine. This magnetic field interacts with the armature winding, which carries the electric current and generates mechanical power. The field winding typically has fewer turns of thicker wire compared to the armature winding, which has more turns of thinner wire to handle higher currents.


What would be the shunt field current of your motor if the shunt field winding is excited by?

It could be anything, it depends on the design of the motor and whether it is a high-power or a low-power motor.


What would the power loss be if the series field winding of dc motor connected directly across the 240 V dc supply?

Detailed Solution. For a constant back emf, flux is inversely proportional to the speed of the motor. If field winding is disconnected accidentally, the speed would dangerously increase in order to maintain the back emf of the motor


What is the function of a power plant in a city?

The supply of power to that city.


Why is speed not normally used to control the armature voltage of a synchronous alternator?

Because if speed was used, the power system frequency would be changed. A synchronous generator spins at synchronous speeds. Synchronous generators 101: A typical synchronous generator will have a field winding (typically on the rotor, or rotating part) and a stator winding (the stationary part where power is supplied to the power grid). Current is injected into the field winding, turning it into an electromagnet. This field current is controlled by the Automatic Voltage Regulator (AVR). The more current supplied to the field winding, the stronger the electromagnet becomes, and the more power is required from the prime mover (whatever is supplying the power - steam turbine, for example) to keep the generator spinning at synchronous speeds.


What are field windings and armature windings in a dc motor and generator?

generators have two types of winding , * at armature also called armature winding( winding around shaft , we can say), which is the moving part. note that armature also consists of magnets along with windings. hence produces field arount it. * and at stator also called field winding, because when armature rotates its flux(field) is cutted by the stator windings and produces mutually induced e.m.f in it( in stator windings off course) causing current to flow. this current also produces some electric field around it which is in return cutted by the armature windings hince a little amount of e.m.f ( also called back e.m.f) produced in armature due to stator winding current. know this current in armature (due to back e.m.f produced by stator winding) produces additional field , hence causing more current in stator winding. this is the reason that why stator windings are called field winding( as they cause electric field of armature stronger and cause more current in output). note that out put is taken from the stator windings in generators.


Does the primary winding VA equal the secondary winding VA when a transformer is loaded?

No, the primary winding VA does not necessarily equal the secondary winding VA when a transformer is loaded. The power output on the secondary side may differ from the power input on the primary side due to losses such as resistive and core losses in the transformer. The transformer's efficiency will determine how close the VA on the primary winding is to the VA on the secondary winding.


What will happen if field winding of attenuator gets open?

If the field winding of an attenuator gets open, the attenuator will not be able to control its attenuation level properly. This could result in erratic or no attenuation of the signal passing through the attenuator, leading to unpredictable behavior in the circuit or system it is a part of. Repair or replacement of the attenuator may be necessary to restore proper functioning.


What is steam power plant function?

doing porno is good


What is the purpose of 'Winding Resistance Test' in Electrical Power Engineering?

For calculation of I^2R losses nd it is also used for to evalute the damage in field