Your pump has a leak and the water in the pressure tank is going back down into your well. The only other possibility is that you have a leaking pipe in/under your house. If that's the case, get it fixed immediately or you will have irreversible mold damage.

User Avatar

Wiki User

17y ago

What else can I help you with?

Continue Learning about Engineering

How do you know if a pressure reducing valve is bad?

A pressure reducing valve may be faulty if you notice fluctuating water pressure, consistent water hammer, or leaks around the valve. Additionally, if the pressure gauge shows significantly higher or lower readings than expected, or if there are issues with appliances that require specific pressure levels, it could indicate a problem. Unusual noises or difficulty adjusting the pressure can also signal a malfunctioning valve.


Do you need a pressure gauge on your well pump?

Yes, a pressure gauge on your well pump is important as it helps monitor the water pressure in the system, ensuring it operates efficiently. It can alert you to potential issues, such as low pressure indicating a problem with the pump or well, or high pressure that could lead to system damage. Regularly checking the gauge can help maintain optimal performance and extend the lifespan of the pump.


How do you increase well water pressure?

This is done at the pressure tank. First drain the tank with pump off, then check air pressure at the tank top nipple. It should be above 26 psi. If not this is your problem. You may need a new tank or it it's a 'galvanised ' tank , a new air charge. You may also need the pressure switch adjusted, or even a new one. -Call a well technician for an expert opinion and repair.This is done at the pressure tank. First drain the tank with pump off, then check air pressure at the tank top nipple. It should be above 26 psi. If not this is your problem. You may need a new tank or it it's a 'galvanised ' tank , a new air charge. You may also need the pressure switch adjusted,or even a new one.-Call a well technician.


Do you have a problem your well Water Pump Pressure Control Switch is making a lot of noise and you have a lot of air in your water lines?

You need to switch off the pump, drain the pressure tank and fit a new pressure switch. They are cheap and often last only a few years. When re fitting make sure the pressure tank residual pressure is about 2 PSI LESS than the pressure switch ON setting. In most domestic wells systems the pressure switch comes ON at 30 PSI, so the tank air should be 28 or so..


Why when you turn on the hot water in the shower no water comes out at all the cold works fine but there is no water or pressure on the hot side?

This is probably a pressure imbalance problem or you have air in the lines. see the related video link provided.

Related Questions

What are the common causes of waterlogged pressure tanks and how can they be prevented or resolved effectively?

Common causes of waterlogged pressure tanks include a faulty air valve, a ruptured bladder, or excessive water pressure. To prevent or resolve this issue effectively, regularly check and maintain the air valve, ensure the bladder is intact, and adjust the water pressure to the recommended levels. If the tank is already waterlogged, draining and recharging the tank with the correct air pressure can help resolve the problem.


How do you get more water pressure with well water when you have more than faucet running?

The water pressure is controlled by your pressure switch and the tank residual air. If there is less or low pressure with more than one faucet do a test. 1. switch off the pump. 2 drain the tank through regular faucet, then measure air pressure on nipple at top of tank, if it is less than 26-28 psi that is your problem and may mean the bladder is shot. It can be recharged with a small compressor to 26-28 psi. but this will only last a few weeks if bladder is faulty.The water pressure is controlled by your pressure switch and the tank residual air. If there is less or low pressure with more than one faucet do a test. 1. switch off the pump, drain the tank through regular faucet, then measure air pressure on nipple at top of tank, if it is less than 26-28 psi that is your problem and may mean the bladder is shot. It can be recharged with a small compressor to 26-28 psi. but this will only last a few weeks if bladder is faulty.


Renault megane II check gearbox?

Common problem have Solenoid replaced Usually the pressure regulator valve.


How do fish's swim bladders adjust to differences in fluid density?

The swim time course of the swim bladder response raises a problem. If a fish can not instantly adjust its swim bladder volume its buoyancy is unstable. As the fish rises in the water the pressure of the swim bladder decreases!


Replaced oil pressure sensor on 98 Tahoe now fuel pump will not quit running even with key off?

Had the same problem - turned out we bent one of the prongs on the oil pressure switch when we were connecting it.


What were the goals of Martin Luther King jrs poor people's campaign that he was leading when he was assassinated?

to pressure the nation to address the problem of poverty


How do you tell if the foot valve is bad or the bladder tank?

To determine if the foot valve or bladder tank is faulty, check for signs of water leakage or air pressure issues. If the bladder tank is losing pressure rapidly or shows waterlogging (water in the tank without air), it may be the problem. Conversely, if the pump runs continuously or cycles frequently without achieving the desired pressure, the foot valve might be stuck open or damaged. Inspect both components for physical damage, and test the system under operation to isolate the issue.


Why would my oil pressure gauge on my 2002 corvette be readinfg at the highest level?

I have a 98 with the same problem. The sensor in the engine needs to be replaced.


Caterpillar 3306 oil pressure problem?

I have no number on panel when icon checks oil pressure . please guide me what is problem


You just had your fuel tank replaced and now your check engine light just came on What could be the problem?

Probably the fuel pressure sensor malfunctioning...


I replaced a 1991 Nissan 204sx slave cylinder. Now it will not build up pressure and the pedal stays to the floor. What is the problem?

You need to bleed the clutch


The change oil light comes on and the truck just had an oil change what could be the problem?

Not enough oil was replaced. If this is not the case then oil pressure may be low.