answersLogoWhite

0

Sinusoidal loads are preferred over square loads primarily due to their smoother waveform, which results in less harmonic distortion and reduced stress on electrical components. This leads to improved efficiency and lower heating in both the load and the power system. Additionally, sinusoidal loads facilitate easier analysis and control in AC systems, making them more compatible with standard power generation and distribution methods. Overall, they enhance system reliability and performance.

User Avatar

AnswerBot

1mo ago

What else can I help you with?

Continue Learning about Engineering

What is mean by non sinusoidal load?

A load that is not sinusoidally varying (i.e. resembling that of a graph of the function sin(x) or cos(x)). This means the load is not cycling or periodic so it does not repeat itself over and over - which is exactly what the graph of the trig function sin(x) demonstrates.


What is load pressure?

Load pressure refers to the force exerted by a load over a specific area, typically measured in units such as pascals (Pa) or pounds per square inch (psi). It is an important concept in engineering and construction, as it helps determine how weight and stress are distributed across surfaces and structures. Understanding load pressure is crucial for ensuring structural integrity and safety in various applications, from building design to machinery operation.


What is direct loading?

direcly puting a load with out any control over the load once applied difficult to take out


Can i Over load an oil filled transformer?

Any transformer can be overloaded by applying a load above the capacity rating of the transformer.


Where are periodic signals used?

A periodic signal is a signal that repeats itself over a fixed period of time such as a sinusoidal, square, triangular or sawtooth waveform. So, basically they are used in almost every application of electrical engineering. These periodic waveforms, are also responsible for driving oscillators which is very important in computer applications where a CPU may need to operate according to the clock speed that is determined by the oscillator.

Related Questions

What is mean by non sinusoidal load?

A load that is not sinusoidally varying (i.e. resembling that of a graph of the function sin(x) or cos(x)). This means the load is not cycling or periodic so it does not repeat itself over and over - which is exactly what the graph of the trig function sin(x) demonstrates.


What is mean by non-sinusoidal load?

A load that is not sinusoidally varying (i.e. resembling that of a graph of the function sin(x) or cos(x)). This means the load is not cycling or periodic so it does not repeat itself over and over - which is exactly what the graph of the trig function sin(x) demonstrates.


How do you determine rms and .707 in electricity?

In electricity, the root mean square (RMS) value is calculated by taking the square of the instantaneous values of a waveform over a complete cycle, averaging those values, and then taking the square root of that average. For a sinusoidal waveform, the RMS value can also be determined by multiplying the peak voltage (V_peak) by 0.707 (or 1/√2). This factor represents the ratio of the RMS value to the peak value for sinusoidal signals, where the RMS value effectively represents the equivalent DC value that would produce the same power in a resistive load.


Why do businesses prefer to make purchases on credit?

Because it is easier than handing over a load of cash.


What is the RMS value of AC sinusoidal waveform?

General formula: square root of the square modulus averaged over a period:xRMS =1/T sqrt( integral (|x(t)|2dt) ) ,where x(t) is the signal and T is its period.If you solve it for sinusoidal waves, you get a 1/sqrt(2)~0.707 factor between peak amplitude and RMS value:xRMS ~ 0.707 XPK ~ 0.354 XPK-PK ~ ...


Why this rms voltage is 0.707 times peak voltage?

The root mean square (RMS) voltage is 0.707 times the peak voltage for a sinusoidal waveform because of the mathematical relationship between peak and RMS values. The RMS value is calculated as the peak value divided by the square root of 2 for a sinusoidal waveform. This factor of 0.707 ensures that the average power delivered by the AC voltage is the same as the equivalent DC voltage for resistive loads. This relationship is crucial for accurately representing and analyzing AC voltage in electrical systems.


How do you prefer your eggs cooked: over well or over hard?

I prefer my eggs cooked over hard.


When was Over Load created?

Over Load was created on 2009-05-13.


What is the definition of wavelenghth?

In physics, the wavelength of a sinusoidal wave is the spatial period of the wave-the distance over which the wave's shape repeats.


What is the simple present of prefer?

The simple present of "prefer" is "prefer." For example, "I prefer coffee over tea."


What is driver over load?

too much load


What is noncontinuous load?

A continuous load is a constant load. A noncontinuous load is one that varies over time.