The number of fixture units that a 4-inch horizontal pipe can accommodate varies based on Plumbing codes and the type of fixtures connected. Generally, a 4-inch pipe can handle around 40 to 50 fixture units, depending on factors like the length of the pipe and the specific code provisions in your area. To get an accurate assessment, it's best to consult local plumbing codes or a plumbing engineer.
Since a hexagon is a horizontal plane figure it cannot have a horizontal plane of symmetry.
There are 2 horizontal parallel lines in the letter Z
13*9 = 117 square units
There are: 13*9 = 117 square units
8
well kitchen sinks are set at 2 fixture units and on a 2" drain you can have 4 because horizontal 2" line can have 8 fixtures units and 2" vertical can have 16 fixture units.
The plumbing code adopted by the jurisdiction in which the piping is placed will assign a "fixture unit" value to fixtures. For example, for waste and vent piping, a lavatory is usually one, a sink is usually two, a toilet usually between three and six, etc. A chart in the code book will tell how many "fixture units" can be installed on a particular size line. For example, a 2" line will usually carry 16 fixture units on a vertical pipe, 8 fixture units on a horizontal pipe, and will vent 24 fixture units. For a specific answer to your need you should consult a plumber working in your jurisdiction. And as far as "certain distances".....horizontal is self-limiting by grade, vertical is addressed by code, for example, 2" is limited to 85 feet vertical. Pressure pipe (water) is done much the same way....fixture unit values assigned to fixtures and then total fixture units allowed for each pipe size and pressure range.
16 sq. inches
What is the condendsate in GPM flow and what tonnage is the unit
It will Carry 10
That would depend on the fixture units each fixture has and the developed length of the vent piping
That would depend on local codes... I fiqure 2 fixture units and even if the code allow the use of 11/2" diameter pipe I always use 2" MIN.
Because the drainage system is over loaded by to many fixture units
10,784 drains can be connected to a main vent give or take depending on the fixture units and the developed lenght 10,784 drains can be connected to a main vent give or take depending on the fixture units and the developed lenght
92
The denominator (the figure below the horizontal line)
That would depend on how many drainage fixture units you want to drain and which LOCAL code your using.