In a certain sense oscilloscope probes are already being used in medicine today. An oscilloscope is simply a machine that visually represents changes in voltage. Thats what EKG and EEG machines do - they measure the electrical activity in your heart and brain respectively and use probes to do it.
The resistance of an ideal oscilloscope probe is infinity.
Oscilloscope probe compensation is the process of adjusting the probe to match the input capacitance of the oscilloscope, ensuring accurate waveform measurements. This is done by using a compensation signal to adjust the probe's circuitry for optimal signal fidelity. Proper probe compensation is essential for obtaining accurate and reliable measurements with an oscilloscope.
You can get information on how to do repairs on your oscilloscope probe online. One such website is http://www.radio-electronics.com/info/t_and_m/oscilloscope/oscilloscope_probes.php. The oscilloscope probe is mechanical part of scope. It does not have any electronic circuit. It is better to contact manufacturer for repairs of your probe. In all probabilities you will need replacement than repair as lenses, and fiber-optic cables do not get repaired.
A standard oscilloscope is designed to measure voltage, you need a current probe for your oscilloscope to measure current.
Beware using ground clips for high speed measurements.Beware of oscilloscope bandwidth limitations.Ensure the correct triggering.Use the right oscilloscope probe.Remember to calibrate the oscilloscope probe.Beware using ground clips for high speed measurements.Beware of oscilloscope bandwidth limitations.Ensure the correct triggering.Use the right oscilloscope probe.Remember to calibrate the oscilloscope probe.
Teledyne LeCroy manufacturers oscilloscope probes. Teledyne LeCroy also offers an option to have a oscilloscope probe serviced with them if there is ever an issue.
To measure using an oscilloscope, connect the oscilloscope probe to the signal source. Adjust the time and voltage scales on the oscilloscope to properly display the waveform. Use the cursors and measurements feature on the oscilloscope to measure parameters like frequency, amplitude, rise time, and pulse width.
To tell you the state of a logic signal, when the state changes are infrequent and the cost of an oscilloscope or logic analyzer would be inappropriate/excessive.
1. beacon is used to serve the purpose of association services where as a probe is used to serve the purpose of reassociation services. 2. beacon is used in registration procedures whereas a probe is used in handoff procedures. by Yusuf Javed Mob. +919893872319
Yes, the probe of a fish can enter the mouth cavity. Fish have a structure called the buccal cavity, which is part of their mouth, where the probe can be inserted to examine internal features or conditions. This can be useful for research or medical purposes, such as studying feeding habits or assessing health. However, care must be taken to avoid harming the fish during such procedures.
the laserphaco is a medical device that Patricia Era Bath invented
Essentially you have to make a device that doesn't load down the circuit being tested and adapts to the input configuration of your oscilloscope. Start with a suitable length of coaxial cable with a BNC connector attached to one end. In order to present a high-impedance to the probe tip and simultaneously scaling the sensitivity of the 'scopes input, you will need to construct a voltage divider circuit at the other end of the coax. This voltage divider circuit could be for instance a 5 mega ohm resistor in series with the core of the coax and a probe tip along with a 1 meg resistor in parallel with the coax conductors. That is, across the shield to the center conductor. A suitable non-conductive handle is used to house the voltage divider, which has the other end of the 5 meg resistor attached to a pointed object of some type that extends from the end of the probe handle. A short length of wire with an alligator clip attached to the end is then soldered to an exposed section of coax shield thus forming the ground reference for the probe. A suitable housing for the probe could be a plastic writing pen that has been gutted for this purpose. A web site that shows this operation can be found at http://www.cromwell-intl.com/radio/probes.html where I found this clever ascii artwork that explains what is described above: R1 5 Mohm ---------------------- test <----/\/\/\/\----+-----------(o) )--- scope input point | +--------------------+ ~ 1 Mohm | | 50-75 ohm | 10-20 pF +--/\/\/\/\-- + cable | 1.25 Mohm | | R2 | | ----- ----- --- --- - - \__________________________/ \______________/ \_____________/ | | | Probe Cable Oscilloscope