Heat fixing is not used in flagellar staining because it can damage the fragile flagella, leading to their distortion or loss. Flagella are delicate structures, and heat can denature proteins and alter their natural configuration, making it difficult to visualize them accurately. Instead, flagellar staining techniques typically rely on chemical fixation or simply allow the cells to adhere to the slide without heat treatment, preserving the integrity of the flagella for observation.
you need to sync the ipod, if still dont appear try transfering the apps to the computer
There are many websites for buying Cds and some songs are available at Itunes.
yes they do,if your eyelashes are longer your eyes stand out better and look prettyer but dont worry if yours arent that long a bit mascara can fix that in no time(:
If you replaced it with an aftermarket unit,,,, Put it back!,,,,,,,,,,,,,,,,,,,,, If its just A different factory unit, Then it likely has A code, Check with the dealer.,,,,,,,,,,, If you had A company do the changeover then they need to fix this problem unless they warned you that it may do this.
take it to the fix it man! he should glue it up and sand it off, the crack will have gone it it will almost be invisible if its done well. dont leave it else the crack will expand and the tuning will go!
If no heat fixing was done to a slide with a specimen on it, it would be rinsed off with the gram staining procedure. Heat fixing the specimen does kill specimen but it also locks it in place.
You absolutely do not heat fix a blood smear before staining, that is, if you are looking at the blood cells. For bacteria, why wouldn't you culture it first and then heat fix, stain etc. I don't think heat fixing the blood stain would damage the bacterial cells so much as make it hard to differentiate the bacterial cells from the dead, shriveled, ruined blood cells, unless maybe you have like an electron microscope or something.
If a bacterial smear is not heat fixed prior to staining, the bacteria may not adhere well to the slide and can wash away during the staining process. Heat fixing helps to kill the bacteria, firmly attach them to the slide, and improve the uptake of stain, resulting in better staining results. Without heat fixing, the bacteria may not stain properly or may not be visible at all under the microscope.
Passing the bacterial smear through the flame before staining is done to heat-fix the bacteria onto the slide, making them adhere firmly and preventing them from washing off during the staining process. Heat fixing also kills the bacteria, which helps in the preservation of their cellular structures for visualization under the microscope.
You heat fix a slide by passing it through a blue flame a couple of times (with th cells facing up). you do this to denature any enzymes that might lyse the cells or interfere with the staining procedure. you also use it kill the organism and to adhere the organism to the slide for staining
Heat is applied to fix bacterial cells to slides because it kills the bacteria and adheres them to the glass, allowing for better staining and visualization. In contrast, animal cells are usually more delicate and can be adversely affected by heat, which may cause them to rupture or lose their structural integrity. Instead, animal cells are typically fixed using chemical fixatives, which preserve their morphology without damaging them.
Capsular material is very moist (slimy) and any heating will cause it to shrink - it is for this reason that we will not heat fix the slide before staining. Also, heating may cause the bacterial cell to shrink resulting in a clear zone around the cell - which may cause cells which don't have capsules to appear as if they do.
Without heat fixing, the bacteria on the slide will not adhere properly, leading to poor attachment to the slide during staining. This may result in uneven staining, leading to difficulty in visualizing the bacterial cells clearly under the microscope. Proper heat fixing ensures that the bacteria are securely attached to the slide, allowing for better staining and clearer observation under the microscope.
It is used to fix because to make the cell inactive or immoblie, but the main purpose is to fix the smear so that when we put stain and then flush it out with water ( or some time with alcohol) the smear should not wash out with dye.
If you forget to heat fix your slide your bacterial sample will be lost with the next wash step. So if you are doing a Gram stain when you add the crystal violet the liquid will mix with the bacteria, and when you wash later in the protocol the bacteria will wash away with the stains.
Heat-fixing in gram staining serves to adhere bacterial cells to the slide, making them more resistant to washing off during the staining process. It also helps to kill the bacteria, allowing them to take up the crystal violet stain more effectively. Additionally, heat-fixing can alter the permeability of the bacterial cell wall, aiding in the retention of the stain through subsequent decolorization steps.
In order to heat fix your microbe to your slide - you need to let your smear air dry. Once it is completely air dried. Pass the slide 2 or 3 times quickly over an open flame like a Bunsen burner. This does three things, 1. Kills the bacteria 2. Firmly affixes the smear to the microscope slide. 3. Allows the sample to more readily take up the stain.